Home > ELECTRICAL > ROUGH ELECTRICAL > PANEL BOXES > BREAKER BOXES
Sort By:
1
Square D QO2L30SC Load Center PowerMark Gold TL412C Standard Load Center Homeline Square D HOM24L70S Load Center
Main lug load center, indoor, 30 amp, 2 spaces/2 circuits. Accommodates both overhead and underground feed applications. 1" maximum knockout on the top and bottom of the enclosure. Comes with a doorless surface mount cover and factory installed main lugs. UL Listed. Single-phase, three-wire, 120/240 volt AC. (4) 1" circuits or (8) 1/2" circuits. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. Minimum 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2" THQPs. 10,000 AIC. 40 - 225 amp single phase devices have removable closing caps. TL load center enclosures are galvanized steel. 7-1/4" x 9" x 3". UL Listed. Main lug indoor load center, 70 amp, 2 spaces/4 circuits. Maximum SCCR of 10,000 and a maximum load of 240 volts. NEMA type 1 enclosure. Expandable loadcentre capacity with the use of tandem or quad breakers. CSA approved for vertical, horizontal or inverted mounting. Accepts aluminum or copper conductors. Approved to only accept Canadian HomeLine breakers.
Homeline Square D HOM24L70F Load Center Eaton BR24L70SP Load Center Eaton BR24L70FP Load Center
Main lug indoor load center, 70 amp, 2 spaces/4-circuits. NEMA type 1 enclosure with a flush mount cover. Overhead or underground feeds with 1-1/4" knockouts in both the top and bottom endwalls. Compatible with Homeline 1 pole and tandem breakers and a PK3GTA1 ground bar kit (not included). UL Listed. Steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 2 (1") spaces, 4 poles, 120/240 volt. No.GBK5 or GBK520 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #8 - #2 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 5 box 4-1/2" x 9-7/16" x 3". UL Listed file E8741. Single phase, 3 wire, insulated/bondable neutral, 2 (1") spaces, 4 poles, 120/240 volt AC. No. GBK5 or No. GBK520 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #8 - #2 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 5 box 4-1/2" x 9-7/16" x 3". UL Listed file E8741.
Cutler Hammer BRL200 Main Lug Kit Square D QO24L70S Load Center Homeline Square D HOM612L100S Load Center
Two pole - 200 amp - pair. Main lug load center, intended for fixed applications. 70 amp, 2 spaces/4 circuits. Surface mount cover with door and a NEMA type 1 enclosure for indoor use. Single phase unit, features a copper bus for conductivity and is rated for up to 10,000 SCCR. ANSI Certified and UL Listed. Main lug indoor load center, 100 amp,  6 space/12 circuit. NEMA type 1 enclosure.  Single phase, 3 wire, solid neutral. Expandable loadcentre capacity with the use of tandem or quad breakers. CSA approved for vertical, horizontal or inverted mounting. Accepts aluminum or copper conductors. Approved to only accept Canadian HomeLine breakers.
PowerMark Gold TLM612FCUD Standard Convertible Load Center Homeline Square D HOM612L100F Load Center Eaton BR48L125FP Load Center
Indoor flush or surface mount with door. Box is significantly smaller and lighter while maintaining optimum wire-bending space. Side mounted main  breaker allows top or bottom feed. Sturdy copper bus and galvanized box increase durability and reliability; tinplated for corrosion resistance. Minimum 100 per cent neutral terminations. All neutral holes rated for 14-4 wire. Extruded neutrals are easier to wire, reducing installation time and cost. Combination slotted/Robertson screws speed wiring. Accepts GE Q-Line branch circuit breakers, including GE's exclusive 1/2" THQPs. Interior removes and reinstalls easily. Main breaker not included. (6)  1" circuits or (12)  1/2"  circuits. 12-5/8" x 12-3/8" x 3-3/8". UL Listed. Main lug indoor load center, 100 amp, 6 space/12 circuit. 1-1/2" knockouts in the top and bottom end walls to allow for use with either overhead or underground fed electrical wiring. 22,000 short circuit current rating (SCCR) and can be fitted with a secondary surge arrestor (not included) for added protection. Single phase, 3 wire, solid neutral. UL Listed. Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 4 (1") spaces, 8 poles, 120/240 volt. No.GBK10 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service application. #14 - 1/0 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741.
Eaton BR48L125SP Load Center Murray LC004NSU Load Center Eaton BR24L70RP Load Center
Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 4 (1") spaces, 8 poles, 120/240 volt. No. GBK10 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service application. #14 - 1/0 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741. Single phase - 3 wire; 120/240 volt;  8 circuits maximum with 4 - 1" spaces. 14" length x 8-1/2" width x 3-1/4" depth. 10,000 AIC. UL listed. Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 2 (1") spaces, 4 poles, 120/240 volt AC. With closure plates, hubs and No.GBK5 or GBK520 ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #8 - #2 wire range. Electrostatic powder coat, baked urethane painted. 4-1/2" x 9-7/16" x 3". UL Listed file E8741. Style 5R box.
Eaton BR612L125FDP Load Center Square D QO612L100FCP Load Center Square D QO612L100SCP Load Center
Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 6 (1") spaces, 12 poles, 120/240 volt. Furnished with door; No. GBK10 ground bar sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. Number 14 - number 1 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741. Main lug indoor load center, 100 amp, 6 space/12 circuit, intended for use in fixed applications. NEMA type 1 enclosure and a copper bus bar for conductivity. Single-phase, rated for up to 240 volts and has a 10,000 maximum SCCR. UL Listed. Main lug indoor load center, 100 amp, 6 spaces/12 circuits. 1-1/2" maximum knockouts in the top and bottom end walls for overhead or underground feed. NEMA type 1 for indoor use. Steel enclosure. Single phase, solid neutral. UL Listed.
Homeline Square D HOM24L70RB Load Center Siemens E0204ML1060SU Load Center Siemens E0408ML1125SU Load Center
Main lug outdoor load center, 70 amp, 2 space and 4 circuit. NEMA type-3R enclosure with a rainproof cover for outdoor use. Class 1170 unit is intended for use in fixed applications and can accommodate overhead or underground feed. Maximum SCCR of 10,000. ANSI Certified and UL Listed. Single phase, 3 wire, solid neutral, 2 spaces and 4 circuits maximum 1-pole, 1 QP breaker maximum 2-pole, 120/240 volt AC. 10,000 AIR. One piece plated aluminum bus bar, heavier main bus for cooler operation, direct cable connection to bus bar. Main lugs and neutral on same plane, same drive tool. 100 percent circuit breaker twistouts. Positive load side circuit breaker hook rail. When used as service equipment, any unused neutral position may be used for equipment grounding. Simple upper pan adjustment after trim is installed for flush leveling. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. UL Listed, complies fully with NEC and UL requirements for Class CTL. 5-1/8" x 9-7/8" x 2-5/8". Code-gauge steel enclosure. Single phase, 3 wire, solid neutral, 4 spaces and 8 circuits maximum 1-pole, 2 QP breakers maximum 2-pole, 120/240 volt. 10,000 AIR. One piece plated aluminum bus bar. 100 percent circuit breaker twistouts. Positive load side circuit breaker hook rail. Suitable for use as service equipment when a main breaker (100 amp maximum) is back-fed in a branch position and used with main breaker retainer clip No.MBR1. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. 6-5/8" x 12-5/8" x 3-1/2". UL Listed, complies fully with NEC and UL requirements for Class CTL.
Eaton BR816L125FP Load Center PowerMark Gold TL240RCU Standard Load Center PowerMark Gold TL270RCUP Standard Load Center
Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 8 (1") spaces, 16 poles, 120/240 volt. No.GBK10 ground bar and door sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when a main breaker is used or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #14 - #1 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741. Single-phase, three-wire, 120/240 volt AC. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE 1/2" THQP. (2) 1" or (4) 1/2"  spaces; 22,000 AIC. 7-1/4" x 10" x 3-31/4". One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. Minimum 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100-percent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2"  THQPs. (2) 1" or (4 )1/2" spaces; 22,000 AIC. Single-phase, three-wire, 120/240 Volt AC. 7-1/4" x 10" x 3-3/4".
Eaton BR612L125RP Load Center Eaton BR816L125SDP Load Center PowerMark TPL412RP Standard Load Center
Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 6 (1") spaces, 12 poles, 120/240 volt AC. With closure plates, hubs and No.GBK10 ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when a main breaker is used or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #14-#1 wire range. Electrostatic powder coat, baked urethane painted. Style 7R box 11" x 13" x 3-9/16". UL Listed file E8741. Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 8 (1") spaces, 16 poles, 120/240 volt. Furnished with door. Ground bar No.GBK10 sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when a main breaker is used or when not more than 6 service disconnecting mains are provided and when not used as a lighting or appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #14-#1 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. Minimum 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2"  THQPs. (4) 1" or (8)  1/2"  spaces; 10kAIC. Single-phase, Three-wire, 120/240 volt AC. 7-1/2" x 9-7/32" x 3-5/16".
Murray LW002GRU Load Center Eaton BR48L125RP Load Center PowerMark Gold TLM812FCUD Standard Convertible Load Center
Single phase - 3 wire; 120/240 volt;  4 circuits maximum;  2 - 1" spaces ; 10,000 AIC. 9-1/4" x 6-5/8" x 3-3/8". UL Listed. Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 4 (1") spaces, 8 poles, 120/240  volt AC. With closure plates, hubs, and No.GBK10 ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #14-1/0 wire range. Electrostatic powder coat, baked urethane painted. Style 7R box 11" x 13" x 3-9/16". UL Listed file E8741. Box is significantly smaller and lighter while maintaining optimum wire-bending space. Side mounted main breaker allows top or bottom feed. Sturdy copper bus and galvanized box increase durability and reliability; tinplated for corrosion resistance. Minimum 100 per cent neutral terminations. All neutral holes rated for 14-4 wire. Extruded neutrals are easier to wire, reducing installation time and cost. Combination slotted/Robertson screws speed wiring. Accepts GE Q-Line branch circuit breakers, including GE's exclusive 1/2" THQPs. Interior removes and reinstalls easily. Main breaker not included. (8) 1" circuits or (16) 1/2" circuits. 12-5/8" x 12-3/8" 3-3/8". UL Listed.
Eaton BR24L125RP Enclosed Load Center Eaton BR612L125SP Load Center LOAD CENTR 125A 8SP 16C INDOOR
Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 2 (1") spaces, 4 poles, 120/240 volt AC. With closure plates, hubs and No.GBK5 or GBK520 ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #14-1/0 wire range. Electrostatic powder coat, baked urethane painted. Style 6R box 6-7/8" x 12" x 4-1/2". UL Listed file E8741. Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 6 (1") spaces, 12 poles, 120/240 volt. No.GBK10 ground bar and door sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when a main breaker is used or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance appliance. #14 - #1 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741. Value kit, indoor. Includes a sturdy highly-conductive tin-plated copper buss bar and a rust-resistant galvanized box. Indoor NEMA 1 enclosure with combination surface/flush front. Factory-installed main lug, full-length neutral bars, top or bottom feed and self-adjusting, dead-front cover. One-piece interior removes and re-installs easily. Single-phase, 3-wire, 120/240-volt and 22K AIC rating. All holes are rated for 14-4 wire and 100 percent rated split neutrals on each side. Accepts Q-Line THQL standard, GFCI and AFCI circuit breakers, including GE's exclusive 1/2" THQPs. UL Listed and ANSI Certified. 16" height x 14" width x 3.375" depth, 16.79 lb.
Siemens EQ W0204ML1060U Load Center Murray LW004NRU Load Center Siemens EQ W0408ML1125U Load Center
Single phase, 3 wire, solid neutral, 2 spaces and 4 circuits maximum 1-pole, 1 QP breaker maximum 2-pole, 120/240 volt AC. 10,000 AIR. With closure plates, HS style hubs sold separately, uses ECHA075 (694.3559) Hub. One piece plated aluminum bus bar. 100 percent circuit breaker twistouts. Will not accommodate 2-pole GFCI or circuit breaker with shunt trip. Positive load side circuit breaker hook rail. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. CSA and UL Listed, complies fully with NEC and UL requirements for Class CTL. 5" x 8" x 4-1/4". Convertible to main breaker using double pole breaker. 2 full spaces. 4 space, 8 circuit, combination mount. Code-gauge steel enclosure. Single phase, 3 wire, solid neutral, 4 spaces/8 circuits 1-pole, 2 QP breakers 2-pole, 120/240 volt AC. 10,000 AIR. With closure plates, HS-hubs sold separately. One piece plated aluminum bus bar. 100 percent circuit breaker twistouts. Positive load side circuit breaker hook rail. Suitable for use as service equipment when a main breaker (100 amp maximum) is back-fed in a branch position and used with main breaker retainer clip No.MBR1. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. CSA and UL Listed, complies fully with NEC and UL requirements for Class CTL. 6" x 12-1/4" x 4-1/4".
GE TL412R1P Standard Load Center Murray LC008DSU Load Center Homeline Square D HOM612L100RB Load Center
One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2" THQPs. (4) 1" or (8) 1/2"  spaces. Single-phase, three-wire, 120/240 Volt AC. 7-1/4" x 10" x 3-3/4". Single phase type 1 with 8-1" spaces, 16 circuits. Use neutral lug kit DLK1 or DLK2 as required. Indoor closure with door. Outdoor main lug load center, 100 amp, 6 space and 12 circuits. Can be wired for underground or overhead feeds with a 2-1/2" hub on the top and a 1-1/2" knockout on the bottom. NEMA type 3R enclosure resists rain for durable performance. ANSI Certified and UL Listed.
Eaton CH2L70RP Load Center PowerMark Gold TLM1212CCU Standard Convertible Load Center Square D QO24L70RB Load Center
Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 2 (3/4") spaces, 4 poles with CHNT breakers, 120/240 volt AC. With closure plates, hubs and ground bar No.GBK5 or No.GBK520 sold separately. Copper bus bar. In service entrance application, where neutral is bonded, unused neutral connections may be used for termination of equipment grounds. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. #14 - 2 main lug wire range. Electrostatic powder coated. Style 5R box 4-1/2" x 9-1/2" x 3-1/8". UL Listed file E8741. Box is significantly smaller and lighter while maintaining optimum wire-bending space. Side mounted main  breaker allows top or bottom feed. Sturdy copper bus and galvanized box increase durability and reliability; tinplated for corrosion resistance. Minimum 100 per cent neutral terminations. All neutral holes rated for 14-4 wire. Extruded neutrals are easier to wire, reducing installation time and cost. Combination slotted/Robertson screws speed wiring. Accepts GE Q-Line branch circuit breakers, including GE's exclusive 1/2" THQPs. Interior removes and reinstalls easily. Main breaker not included. 14 spaces, 24 circuits. 14-1/8" x 16-1/8" x 3-3/8". UL Listed. Main lug indoor load center, 70 amp, 2 spaces/4 circuits. Intended for overhead or underground feed. 1-1/4" maximum knockouts in the top and bottom end walls. NEMA 3R enclosure for outdoor use with a factory included cover. Copper bus for conductivity. UL Listed.
Square D QO612L100RBCP Load Center LOAD CENTER 125A 8SPACE 16CIR Siemens E0816ML1125S Load Center
Outdoor main lug load center, 100 amp, 6 space 12 circuit. NEMA type 3R enclosure with a rainproof cover. Copper bus bar, accommodates standard QO or QO tandem circuit breakers. ANSI Certified and UL Listed. Single-phase, Three-wire, 120/240 volt AC. Convertible. Full-length neutrals are easier to wire, reducing installation time and cost. Removable closing cap. Minimum 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2"  THQPs. UL listed. 11-1/4" x 11-1/8" x 3-1/4". Code-gauge steel enclosure. Single phase, 3 wire, solid neutral, 8 spaces and 16 circuits maximum 1-pole, 4 QP breakers maximum 2-pole, 120/240 volt. 10,000 AIR. One piece plated aluminum bus bar. 100 percent circuit breaker twistouts. Positive load side circuit breaker hook rail. Suitable for use as service entrance equipment when a main breaker (125 amp maximum) is back-fed in branch position and used with main breaker retainer clip No.MBR1. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. 12-3/8" x 14-3/4" x 3-7/8". UL Listed, complies fully with NEC and UL requirements for Class CTL.
Square D QO816L100FCP Load Center Square D QO816L100SCP Load Center Eaton BR816L125RP Load Center
Main lug indoor load center, 100 amp, 8 space/16 circuit. 1-1/2" maximum knockouts in the top and bottom end walls to accommodate overhead or underground feed. The center is rated for a maximum load of 240 volts and has a 10,000 SCCR. NEMA type 1. Copper bus for conductivity. Single phase, 3 wire, solid neutral. UL Listed. Main lug indoor load center, 100 amp, 8 spaces/16 circuits. 1-1/2" maximum knockouts in the top and bottom end walls to accommodate overhead or underground feed. Maximum load of 240 volts and a 10,000 SCCR. NEMA type 1. Copper bus for conductivity. Single phase, 3 wire, solid neutral. UL Listed. Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 8 (1") spaces, 16 poles, 120/240 volt AC. With closure plates, hubs and No.GBK10 ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when a main breaker is used or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #14-#1 wire range. Electrostatic powder coat, baked urethane painted. Style 7R box 11" x 13" x 3-9/16". UL Listed file E8741.
Siemens ES S1224L1125 Load Center BRLC 125A 12/24CR AL BUS/WGB  Siemens EQ W0816ML1125CU Load Center
Single phase, 3 wire, Rated 100,000A IR. Aluminum bus bar, tin plated. ANSI 61 gray powder coated. Suitable for use as service equipment when not more than six main disconnecting means are provided. 12 spaces, 24 circuits maximum. 18" height x 14-1/4" wide by 3-7/8" deep. BR style 1-inch loadcenter, main lug, ground bar, includes BREQS125 hold-down screw, 125A, single-phase, 24-pole, 24 circuits, 12 spaces, 120/240V, #6-2/0 AWG Cu/Al at 60 or 75 degreesC wire, NEMA 1 enclosure, b1 box size. Ground bar, includes BREQS125 hold-down screw. 10 kAIC interrupt rating. Aluminum bus, combination mounting. 3.88 in x 14.31 in x 16.75 in. Suitable for use as service equipment when no more than 6 main disconnecting means are provided or when not used as lighting and appliance panelboard. Has notch for brhdk125 hold-down kit. Code-gauge steel enclosure. Single phase, 3 wire, solid neutral, 8 spaces/16 circuits 1-pole, 4 QP breakers 2-pole, 120/240 volt AC. 10,000 AIR. HS-hubs sold separately. One piece copper bus bar, 100 percent circuit breaker twistouts. Positive load side circuit breaker hook rail. Suitable for use as service equipment when a main breaker (125 amp maximum) is back-fed in a branch position, and used with main breaker retainer clip No. MBR1. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. UL Listed, complies fully with NEC and UL requirements for Class CTL. 12-1/8" x 14-3/4" x 4-1/4".
Eaton BR1220B100 Load Center Siemens E1020MB1100FCGP Remodel Load Center PowerMark Gold TLM1212RCUP Standard Convertible Load Center
Galvanized steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 12 (1") spaces, 20 poles, 120/240 volt.  Main breaker type BR at 10,000 AIR. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #4 - 1/0 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. 14-5/16" x 18-3/4" x 3-7/8". UL Listed file E52977. Single phase, 3 wire, 10 spaces/20 circuits, 120/040 volt. 22,000 AIR. Use for older home renovation projects where the distance between the studs are narrower then current construction practices. One piece bus bar construction designed for use only with circuit breakers. Simple dead front adjustment after trim is installed. Positive load side circuit breaker hook rails. Two 15 amp single pole and one 30 amp double pole breakers included. 14-3/4" x 12-3/8"  3-7/8". UL Listed. Factory installed main lug, convertible to a main breaker. Single-phase, three-wire, 120/240 volt AC. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. Minimum 100 per cent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2"  THQPs. 100-225 amp devices have removable closing cap. (12) 1" or (24) 1/2"  spaces; 22000 AIC. 12-1/2" x 21-3/16" x 4-5/8".
Square D QO816L100RBCP Load Center Speedfax S1224B1100 Convertible Load Center PowerMark Gold TM1210CCU Standard Load Center
Main lug outdoor load center, 100 amp, 8 space/16 circuit, has a 2-1/2" maximum type B hub in the top end wall, a 1-1/2" maximum knockout in the bottom end wall and a B-cap covering on the 2" bushed opening. NEMA type 3R enclosure with a rainproof cover for outdoor use. ANSI Certified and UL Listed. Single phase, 3 wire, 22K A/C main breaker factory installed. Aluminum bus bar, tin plated. ANSI 61 gray powder coated. Suitable for use as service equipment when main breaker is installed or when not more than six main disconnecting means are provided. Convertible from main breaker to main lug. NEMA Type 1. 14.25" width x 3.88" depth. Single-phase, Three-wire, 120/240 volt AC. (12) 1" circuits or (24) 1/2" circuits. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. Minimum 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2" THQPs. 100-225 amp devices have removable closing cap. 22,000 AIC. 14" x 19" x 3-3/4". UL Listed.
PowerMark Gold TM2010CCU Standard Load Center BRLC 125A 20/40CR AL BUS/WGB  LOAD CENTER 100A 1P3W 120/240V
Single-phase, three-wire, 120/240 volt AC. (20) 1" spaces. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. Minimum 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson  screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2"  THQPs. 100-225 amp devices have removable closing cap. 22,000 AIC. 14" x 23" x 3-3/4". UL Listed. Type BR single-phase, main lug loadcenters. Three-wire 120/240 Vac. Insulated/bondable split neutral, 20 spaces, 24 circuits, indoor, c1 box size. Has notch for BREQS125 hold-down kit. Combination cover style. Ground bar GBK1220 installed. Value kit, indoor. Includes a sturdy highly-conductive tin-plated copper buss bar and a rust-resistant galvanized box. Indoor NEMA 1 enclosure with combination surface/flush front. Factory-installed main lug, full-length neutral bars, top or bottom feed and self-adjusting, dead-front cover. One-piece interior removes and re-installs easily. Single-phase, 3-wire, 120/240-volt and 22K AIC rating. All holes are rated for 14-4 wire and 100 percent rated split neutrals on each side. Accepts Q-Line THQL standard, GFCI and AFCI circuit breakers, including GE's exclusive 1/2" THQPs. UL Listed and ANSI Certified. 16" height x 14" width x 3.375" depth, 16.79 lb.
Speedfax S2020B1100 Convertible Load Center LOAD CENTR 125A 12SPACE 24CIR BRLC 100A MN 20/40 CR
Single phase, 3 wire, 22K A/C main breaker factory installed. Aluminum bus bar, tin plated. ANSI 61 gray powder coated. Suitable for use as service equipment when main breaker is installed or when not more than six main disconnecting means are provided. Convertible from main breaker to main lug. NEMA Type 1. 14.25" width x 3.88" depth. Value kit, indoor. Includes a sturdy highly-conductive tin-plated copper buss bar and a rust-resistant galvanized box. Indoor NEMA 1 enclosure with combination surface/flush front. Factory-installed main lug, full-length neutral bars, top or bottom feed and self-adjusting, dead-front cover. One-piece interior removes and re-installs easily. Single-phase, 3-wire, 120/240-volt and 22K AIC rating. All holes are rated for 14-4 wire and 100 percent rated split neutrals on each side. Accepts Q-Line THQL standard, GFCI and AFCI circuit breakers, including GE's exclusive 1/2" THQPs. UL Listed and ANSI Certified. 16" height x 14" width x 3.375" depth, 16.79 lb. BR style 1-inch loadcenter, main circuit breaker, no feed-thru lugs, 100A, single-phase, 40-pole, 40 circuits, 20 spaces, 120/240V, #4-1/0 AWG Cu/Al at 60 or 75 degreesC wire, Three-wire, NEMA 1 enclosure, d1 box size. Interrupt Rating 25 kAIC. Aluminum bus. Combination mounting. 5.19 in x 14.31 in x 25 in. UL 50, UL 67. Cover included.
Speedfax S2040B1200 Convertible Load Center Square D QO112M100C Load Center Murray LC2040B1100 Rock Solid Load Center
Single phase, 3 wire, 22K A/C main breaker factory installed. Aluminum bus bar, tin plated. ANSI 61 gray powder coated. Suitable for use as service equipment when main breaker is installed or when not more than six main disconnecting means are provided. Convertible from main breaker to main lug. NEMA Type 1. 14.25" width x 3.88" depth. Welded sheet steel. Single phase, 3 wire, split neutral, 12 spaces/12 circuit, 120/240 volt. 22,000 AIR factory installed main breaker. Comes with a ground bar and a combination cover for added protection. Shielded copper bus bar. 2-1/2" knockouts located on the top and bottom. Accepts QO circuit breakers and is compatible with overhead and underground service feeds. UL Listed. Main breaker load center. 100 amp Single phase, 3 wire, split neutral, 20 spaces/40 circuits. 120/240 volt. Indoor with combination surface/flush cover. 22,000 AIC rating. Aluminum bus bar. One piece steel interior allows for easy removal. Keyhole and nail slots provide easy enclosure mounting. Knockout patterns sized for maximum wiring flexibility. UL Listed.
Eaton BR1224L200R Load Center BRLC 200A 20/40 CR ALBUS/WGB  LOADCENTER 100A 20/40 VP
Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 12 (1") spaces 24 poles, 120/240 volt AC. Has notch for No.BRHDK125 hold down kit. With closure plates, hubs and ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 6 main disconnecting means are provided and when not used as lighting and appliance panelboard. Twin neutral with non-removable cross bus. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #1 - 300 kcmil wire. Electrostatic powder coat, baked urethane painted. B2R box 14-5/16" x 18-3/4" x 5-3/16". UL Listed file E52977. BR style 1-inch loadcenter, main lug, ground bar, includes BREQS125 hold-down screw, 200A, single-phase, 40-pole, 40 circuits, 20 spaces, 120/240V, #1-300 kcmil Cu/Al at 60 degreesC or 75 degreesC wire, three-wire NEMA 1 enclosure, c2 box size. Cover included. 3.88 in x 14.31 in x 23 in. Has notch for brhdk125 hold-down kit. BR style 1-inch loadcenter, main circuit breaker, value pack, 100A, single-phase, 40-pole, 40 circuits, 20 spaces, 120/240V. Wire size #4-1/0 AWG Cu/Al at 60 or 75 degreesC, NEMA 1 enclosure, d1 box size. Aluminum bus, combination mounting. 3.88 in x 14.31 in x 18.75 in. Includes 6-br120. Cover included.
Eaton BR1020B100RF Load Center Murray LC1224B1100 Load Center Siemens Energy MC1020B1100S Meter Socket Load Centers
Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 10 (1") spaces, 20 poles, 120/240 volt AC. Main breaker type BR at 10,000 AIC. Includes feed thru lugs for both phase and neutral conductors. With hub closure plates, hubs and ground bar kit (necessary for sub-feeding) sold separately. Tin plated aluminum bus bar. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #4 - 1/0 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. 14-5/16" x 18-3/4" x 5-3/16". UL Listed file E52977. Single phase 3 wire; 120/240 volt; 24 circuits maximum. Twelve 1" spaces. Combination cover, 10,000 AIC. 100 amp main breaker included. 18-5/8" x 13-1/8" x 4". UL listed. Combination meter socket. Surface mount, overhead service entrance only. 100 amp maximum, 100 amp main breaker installed. Single phase, 3 wire. 10 spaces, 20 circuits, 22,000 AIC rating. Nema type 3R outdoor enclosure. Uses RX style hub, not included.
PowerMark Gold TM820RCUFLP Load Center PowerMark Gold TM2020CCUP Load Center Eaton BR2040B200 Load Center
Factory Installed main breaker. Single phase, three wire, 120/240 volt AC. (8) 1" or (16) 1/2" spaces; 22,000 AIC. One piece interior removes and reinstalls easily. Full length neutrals are easier to wire, reducing installation time and cost. Minimum 100 per cent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE 1/2" THQP. 100-225 amp devices have removable closing cap. 12-1/2" x 28-11/16" x 4-5/8". UL Listed. Single-phase, three-wire, 120/240 volt AC. (20) 1", (40) 1/2" spaces. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2" THQPs. 100-225 amp devices have removable closing cap. 22,000 AIC. 14" x 28-7/16" x 3-3/4". UL Listed. Steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 20 (1") spaces, 40 circuits, 120/240 volt. Main breaker type BWH at 25,000 AIC. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. Number 2 - 300 kcmil wire range. Electrostatic powder coat, baked urethane painted. Orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. UL Listed file E52977. 14-5/16" width x 29-1/8" height x 3-7/8" depth.
Siemens Energy MC1224B1100EFC Meter Socket Load Centers Siemens ES S3030B1150 Convertible Load Center Speedfax S3040B1200 Convertible Load Center
Combination meter socket. flush mount, 100 amp maximum, 100 amp main breaker installed. Single phase, 3 wire. 22,000 AIC rating. Aluminum bus bars. Nema type 3R outdoor enclosure. Complies with EUSERC Dwg. No. 301. Single phase, 3 wire, 22K A/C main breaker factory installed. Aluminum bus bar, tin plated. ANSI 61 gray powder coated. Suitable for use as service equipment when main breaker is installed or when not more than six main disconnecting means are provided. Convertible from main breaker to main lug. NEMA Type 1. 14.25" width x 3.88" depth. Single phase, 3 wire, 22K A/C main breaker factory installed. Aluminum bus bar, tin plated. ANSI 61 gray powder coated. Suitable for use as service equipment when main breaker is installed or when not more than six main disconnecting means are provided. Convertible from main breaker to main lug. NEMA Type 1. 14.25" width x 3.88" depth.
LOAD CNTR 200A 20SP 32C INDOOR Eaton BR816B200RF Load Center Speedfax S3040B1200P Convertible Load Center
Value kit, indoor. Includes a sturdy highly-conductive tin-plated copper buss bar and a rust-resistant galvanized box. Indoor NEMA 1 enclosure with combination surface/flush front. Factory-installed main lug, full-length neutral bars, top or bottom feed and self-adjusting, dead-front cover. One-piece interior removes and re-installs easily. Single-phase, 3-wire, 120/240-volt and 22K AIC rating. All holes are rated for 14-4 wire and 100 percent rated split neutrals on each side. Accepts Q-Line THQL standard, GFCI and AFCI circuit breakers, including GE's exclusive 1/2" THQPs. UL Listed and ANSI Certified. 16" height x 14" width x 3.375" depth, 16.79 lb. Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 8 (1") spaces, 16 circuits, 120/240 volt AC. Main breaker type BWH at 25,000 AIC. Includes feed thru lugs for both phase and neutral conductors. With hub closure plates, hubs and ground bar kit (necessary for sub-feeding) sold separately. Tin plated aluminum bus bar. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #2 - 300 kcmil wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. 14-5/16" x 25" x 5-3/16". UL Listed file E8741. Single phase, 3 wire, 22K A/C main breaker factory installed. Aluminum bus bar, tin plated. ANSI 61 gray powder coated. Suitable for use as service equipment when main breaker is installed or when not more than six main disconnecting means are provided. Convertible from main breaker to main lug. NEMA Type 1. 14.25" width x 3.88" depth.
Square D QO Circuit Breaker Enclosure Speedfax S4040B1200 Convertible Load Center Speedfax S4040B1200P Convertible Load Center
Outdoor circuit breaker enclosure, 200 amp. NEMA type 3R for exterior use. Includes a QOM2200VH circuit breaker and a QOM22225NRB enclosure.  UL Listed. Single phase, 3 wire, 22K A/C main breaker factory installed. Aluminum bus bar, tin plated. ANSI 61 gray powder coated. Suitable for use as service equipment when main breaker is installed or when not more than six main disconnecting means are provided. Convertible from main breaker to main lug. NEMA Type 1. 14.25" width x 3.88" depth. Single phase, 3 wire, 22K A/C main breaker factory installed. Aluminum bus bar, tin plated. ANSI 61 gray powder coated. Suitable for use as service equipment when main breaker is installed or when not more than six main disconnecting means are provided. Convertible from main breaker to main lug. NEMA Type 1. 14.25" width x 3.88" depth.
PowerMark Gold TM2020CCUPL5 Contractor Load Center Kit BRLC 200A 40/40 CR ALBUS/WGB  Murray LC4040B1200 Load Center
Includes 1 number TM2020CCU, 200 amp, indoor load center, 6 THQL single pole 20 amp, 1 THQL double pole 30 amp and 1 THQL double pole 50 amp. 40 maximum 1 pole 1/2" spaces, 20 maximum 1" spaces. UL Listed. BR style 1-inch loadcenter, main lug, ground bar, 200A, single-phase, 40-pole, 40 circuits, 40 spaces, 120/240V, #1-300 kcmil Cu/Al at 60 or 75 degreesC, NEMA 1 enclosure, G1 box size. Aluminum bus, Three-wire. Cover included. 3.88 in x 14.31 in x 34.13 in, 34 lb. Has notch for brhdk125 hold-down kit. UL 67, UL 50. Single phase, 3 wire; 120/240 volt; 40 circuits maximum; 40 - 1" spaces; 10,000 AIC  with combination cover. 200 amp main breaker included. 35-3/4" x 14-1/8" x 4-1/8". UL Listed.
Murray LC2040B1200 Rock Solid Load Center LOAD CNTR 200A 20SP 32C OUTDOR Eaton BR3040B200V Load Center
Single phase, 3 wire, split neutral, 20 spaces/40 circuits. 120/240 volt. 200 amp main breaker loadcenter. Indoor with combination surface/flush cover. 22,000 AIC rating. Aluminum bus bar. One piece steel interior allows for easy removal. Keyhole and nail slots provide easy enclosure mounting. Knockout patterns sized for maximum wiring flexibility. UL Listed. Value kit includes outdoor 200-amp main breaker load center, 3 20-amp single-pole and 1 30-amp double-pole THQP 1/2" circuit breakers. Includes a sturdy highly-conductive tin-plated copper buss bar and a rust-resistant galvanized box. Outdoor NEMA 3R enclosure. Factory-installed main breaker, full-length neutral bars, top or bottom feed and self-adjusting, dead-front cover. One-piece interior removes and re-installs easily. Single-phase, 3-wire, 120/240-volt and 22K AIC rating. All holes are rated for 14-4 wire and 100 percent rated split neutrals on each side. Accepts Q-Line THQL standard, GFCI and AFCI circuit breakers, including GE's exclusive 1/2-in THQPs. UL Listed and ANSI Certified. 34.19" height x 14.69" width x 5.23" depth, 43 lb. Galvanized steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 30 (1") spaces, 40 poles, 120/240 volt. Main breaker type BW at 25,000 AIC. Ground bar kit (necessary for sub-feeding) sold separately. Tin plated aluminum bus bar. Twin neutral with non removable cross bus. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #2 - 300 kcmil wire range. Electrostatic powder coat, baked urethane painted. Rotates 180 degrees for bottom feed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. G1 box - 14-5/16" width x 34-1/8" height x 3-7/8" depth. UL Listed file E52977.
PowerMark Gold TM4020CCU Standard Load Center Eaton BR3040B200 Load Center Homeline Square D SC2040M200C All-in-One Combination Load Center
Single-phase, three-wire, 120/240 volt AC. (40) 1" spaces; 22,000 AIC. One piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2" THQPs. Removable closing cap. 14" x 39-3/16" x 3-3/4". UL Listed. Galvanized steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 30 (1") spaces, 40 poles, 120/240 volt. Main breaker type BW at 25,000 AIC. Ground bar kit (necessary for sub-feeding) sold separately. Tin plated aluminum bus bar. Twin neutral with non removable cross bus. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #2 - 300 kcmil wire range. Electrostatic powder coat, baked urethane painted. Rotates 180 degrees for bottom feed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. G1 box - 14-5/16" width x 34-1/8" height x 3-7/8" depth. UL Listed file E52977. Combination service entrance device (CSED), referred to as an all in one that includes the utility meter socket, main service disconnect, and integral load center in a single enclosure.  Ring type and overhead or underground feed, rated 200A and surface mount. Single phase, 3 wire. 10,000 short circuit rating. 20 space, 40 circuit. Meets EUSERC standards. Service disconnects are supplied factory installed. Supplied with 100 percent branch neutrals. Meets Federal Specification W-P-115c as Type 1, Class 2. Convertible to semiflush with SC200F flange kit (sold separately). Suitable only for use as service equipment. UL Listed.
Murray LC3040B1200P Rock Solid Load Center BRLC 200A MN 40/50 CIR        LOADCENTER 40SPS 200A VP
Single phase, 3 wire, split neutral, 30 spaces/40 circuits. 120/240 volt. Indoor with combination surface/flush cover. Includes 6 single pole and two double breakers. 22,000 AIC rating. Aluminum bus bar. One piece steel interior allows for easy removal. Keyhole and nail slots provide easy enclosure mounting. Knockout patterns sized for maximum wiring flexibility. 200 amp main breaker loadcenter. UL Listed. Main circuit breaker loadcenter; 200 amp, 120/240 volt AC, 50 circuit, 40 spaces, 1-phase. Tin plated aluminum bus. Twin neutral design. Feed-through lug. UL listed. BR style 1-inch loadcenter, main circuit breaker, current design, 200A, single-phase, 80 circuits, 40 spaces, 120/240V, #1-300 kcmil Cu/Al at 60 or 75 degreesC, NEMA 1 enclosure, 6r box size. Metallic, interrupt rating - 10 kAIC. Aluminum bus, three-wire. Includes 3-br120, 1-br230, cover included. 4.5 In x 6.5 in x 11.75 in, 42 lbs.
Square D QOVP1 Load Center Eaton BR2040B200R Load Center Eaton BR3040B200R Load Center
Indoor load center, one QO13040M200C QO 200 amp, 30 space/40 circuit maximum. Tin plated copper bus. Includes a combination cover and five 20 amp, single pole circuit breakers. NEMA type 1 enclosure. UL Listed, ANSI Certified. Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 20 (1") spaces, 40 poles, 120/240 volt AC. Main breaker type BW at 25,000 AIC. Furnished with hub closure plates, hubs and ground bar kit (necessary for sub-feeding) sold separately. Tin plated aluminum bus bar. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #2 - 300 kcmil wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. 14-5/16" x 29-1/8" x 5-3/16". UL Listed file E52977. Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bonded neutral, 30 (1") spaces, 40 poles, 120/240 volt AC. Main breaker type BW at 25,000 AIC. Furnished with hub closure plates, hubs and ground bar kit (necessary for sub-feeding) sold separately. Tin plated aluminum bus bar. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #2 - 300 kcmil wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. 14-5/16" x 34-1/8" x 5-3/16". UL Listed file E52977.
Eaton CH42B200KP Load Center Siemens Energy MC2040B1200EFC Meter Socket Load Centers
Sheet steel enclosure. Single phase, 3 wire, factory bonded split neutral, 42 (3/4") spaces, 42 poles, 120/240 volt. Main breaker type CSR at 35,000 AIC when used with CH or CHP branch breakers. Solid copper bus bar. Twin neutral with cross bus. Unused neutral connections may be used for termination of equipment grounds. Listed for use as service equipment with twin neutral doubling as neutral/ground; remove bonding strap for separate neutral/ground bars for sub-feed applications. Includes combination surface/flush cover. #2 - 300 kcmil wire range. Electrostatic powder coat, baked urethane painted. Rotate enclosure and trim 180 degrees for bottom feed. 14-5/16" x 37" x 3-7/8". UL Listed file E8741. Combination meter socket. MBK200 main breaker. 20 spaces, 40 circuits, ringless meter cover. 36" x 13.9" x 4.9".
   
 