Home > ELECTRICAL > ROUGH ELECTRICAL > FUSES & BREAKERS > CIRCUIT BREAKERS - GFCI
Sort By:
1
HomeLine HOM115GFICP GFCI Circuit Breaker HomeLine HOM120GFICP GFCI Circuit Breaker GFCI INTERUPTER 15AMP 1POLE
GFCI circuit breaker offers protection of entire branch circuits where damp-location shock hazards may exist, as well as Class A overload and short-circuit protection. Class A denotes a GFCI that will trip when a fault current to ground is 5 milliamperes or more. Yellow push to test button. CSA approved. Rated 10,000 AIR and 120/240 VAC. GFCI circuit breaker offers protection of entire branch circuits where damp-location shock hazards may exist, as well as Class A overload and short-circuit protection. Class A denotes a GFCI that will trip when a fault current to ground is 5 milliamperes or more. Yellow push to test button. CSA approved. Rated 10,000 AIR and 120/240 VAC. Tin plated copper stab to create a reliable, permanent and corrosion resistant connection. Ensures its ground circuitry is functioning properly by automatically running diagnostic testing on a periodic basis. Should a problem be detected, the circuit breaker will trip and will need to be replaced. Unit provides protection against overloads, short circuits and ground faults. Class A 5mA ground fault circuit interrupter. Wire range is #14-8 AWG CU/#12-8 AWG AL. UL Listed. 4.5" height x 1.25" width x 3" depth, .479 lb.
GFCI INTERUPTER 20AMP 1POLE   GFCI INTERUPTER 30AMP 1POLE   MES MP120GF Type MP-T GFCI Circuit Breaker
Tin plated copper stab to create a reliable, permanent and corrosion resistant connection. Ensures its ground circuitry is functioning properly by automatically running diagnostic testing on a periodic basis. Should a problem be detected, the circuit breaker will trip and will need to be replaced. Unit provides protection against overloads, short circuits and ground faults. Class A 5mA ground fault circuit interrupter. Wire range is #14-8 AWG CU/#12-8 AWG AL. UL Listed. 4.5" height x 1.25" width x 3" depth, .479 lb. Tin plated copper stab to create a reliable, permanent and corrosion resistant connection. Ensures its ground circuitry is functioning properly by automatically running diagnostic testing on a periodic basis. Should a problem be detected, the circuit breaker will trip and will need to be replaced. Unit provides protection against overloads, short circuits and ground faults. Class A 5mA ground fault circuit interrupter. Wire range is #14-8 AWG CU/#12-8 AWG AL. UL Listed. 4.5" height x 1.25" width x 3" depth, .479 lb. Protects against shock hazard where water and electricity are present. 120 / 240 volts. UL listed. 1 pole, 1" wide.
MES QF120 GFCI Miniature Circuit Breaker Square D QO120GFICP Type QO GFCI Circuit Breaker Square D QO115GFICP Type QO GFCI Miniature Circuit Breaker
For use on circuits where contact with water or another ground is possible while using an electrical device. 120 volt, 1 pole circuit breakers. Intended for protection of entire branch circuits where damp-location shock hazards may exist. The unit features a thermal-magnetic tripping mechanism with a red Visi-Trip indicator to identify a tripped breaker. 120 volt, 10,000 AIR. 1 space per breaker. CSA approved Canadian Square D QO loadcentre. Intended for protection of entire branch circuits where damp-location shock hazards may exist. The unit features a thermal-magnetic tripping mechanism with a red Visi-Trip indicator to identify a tripped breaker. 120 volt, 10,000 AIR. 1 space per breaker. CSA approved Canadian Square D QO loadcentre.
Square D QO130GFI Type QO GFCI Circuit Breaker GFCI INTERUPTER 30AMP 2POLE   MES QF250 GFCI Miniature Circuit Breaker
Intended for protection of entire branch circuits where damp-location shock hazards may exist. The unit features a thermal-magnetic tripping mechanism with a red Visi-Trip indicator to identify a tripped breaker. 120 volt, 10,000 AIR. 1 space per breaker. CSA approved Canadian Square D QO loadcentre. Tin plated copper stab to create a reliable, permanent and corrosion resistant connection. Ensures its ground circuitry is functioning properly by automatically running diagnostic testing on a periodic basis. Should a problem be detected, the circuit breaker will trip and will need to be replaced. Unit provides protection against overloads, short circuits and ground faults. Class A 5mA ground fault circuit interrupter. Wire range is #14-8 AWG CU/#12-8 AWG AL. UL Listed. 3" height x 2.25" width x 4.5" depth, .858 lb. Non-interchangeable trip. GFCI breakers are ideally suited for the protection of hot tubs, spas and other large loads requiring GFCI protection. 120/240 volt.
Eaton GFCB230 Type GFCB Circuit Breaker TBR 1GFI ST BKR 20A2P 120/20V TBR 1GFI ST BKR 30A2P 120/20V
Senses hot wire-to-ground faults in a 4 to 6 milli-ampere range, and shuts off the power. Applications include bathrooms, cellar outlets, swimming pools, outdoor branch circuits, garage and carport areas, and kitchen branch circuits within 6' of the sink. Requires two 1-inch spaces, common trip. UL Listed, Meets UL 489. 120/240 volt AC, 10,000 AIC. GFCB main circuit breaker. BR ground fault self-test. Interrupt rating 10 kAIC. Common trip. 2 pole, requires two 1" spaces. 120/240 volt. Meets Federal Spec Classification W-C375. GFCB main circuit breaker. BR ground fault self-test. Interrupt rating 10 kAIC. Common trip. 2 pole, requires two 1" spaces. 120/240 volt. Meets Federal Spec Classification W-C375.
TBR 1GFI ST BKR 50A2P 120/20V
GFCB main circuit breaker. BR ground fault self-test. Interrupt rating 10 kAIC. Common trip. 2 pole, requires two 1" spaces. 120/240 volt. Meets Federal Spec Classification W-C375.
   
 
1