Home > ELECTRICAL > ROUGH ELECTRICAL > FUSES & BREAKERS > CIRCUIT BREAKERS - SNGL POLE
Sort By:
1
HomeLine HOM140CP Standard Circuit Breaker HomeLine HOM130CP Standard Circuit Breaker HomeLine HOM115CP Standard Circuit Breaker
Single-pole 1" circuit breaker features 10,000 AIR and 120/240 VAC. Uses a thermal-magnetic tripping mechanism for overload and short-circuit protection. Compatible with Homeline load centers and CSED devices. ANSI certified and UL Listed. Single-pole 1" circuit breaker features 10,000 AIR and 120/240 VAC. Uses a thermal-magnetic tripping mechanism for overload and short-circuit protection. Compatible with Homeline load centers and CSED devices. ANSI certified and UL Listed. Single-pole 1" circuit breaker features 10,000 AIR and 120/240 VAC. Uses a thermal-magnetic tripping mechanism for overload and short-circuit protection. Compatible with Homeline load centers and CSED devices. ANSI certified and UL Listed.
HomeLine HOM120CP Standard Circuit Breaker Eaton BR115 Type BR Miniature Circuit Breaker Eaton BR120 Type BR Miniature Circuit Breaker
Single-pole 1" circuit breaker features 10,000 AIR and 120/240 VAC. Uses a thermal-magnetic tripping mechanism for overload and short-circuit protection. Compatible with Homeline load centers and CSED devices. ANSI certified and UL Listed. Switching duty rating. Thermal magnetic 40 degrees C. Interchangeable, will replace: Bryant, Westinghouse and Challenger. Type BR. 120/240 volt, 10,000 AIR. 1" per pole. Switching duty rating. Thermal magnetic 40 degrees C. Interchangeable, will replace: Bryant, Westinghouse and Challenger. Type BR. 120/240 volt, 10,000 AIR. 1" per pole.
MES Q115 Standard Miniature Circuit Breaker GE THQL1120 Type THQL Q-Line Standard Circuit Breaker GE THQL1130 Type THQL Q-Line Standard Circuit Breaker
Non-interchangeable trip. 120 volt AC; 10,000 AIR. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (Full size only), General Switch, I-TE, Gould, Montgomery Ward and Sears. UL Listed, HACR rated. 15 and 20 amp UL Listed for frequent switching applications, 120 volt AC fluorescent lighting.  1" per pole. Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Type THQL - 1" per pole. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger and Crouse-Hinds. 15 to 30 amp 14 - 8 Cu or 12 - 8 Al AWG wire, 35 to 60 amp 8 - 3 Cu or 8 - 2 Al AWG wire. UL Listed, HACR rated. 1" module, 120/240 volt; 10,000 AIR. Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Type THQL - 1" per pole. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger and Crouse-Hinds. 15 to 30 amp 14 - 8 Cu or 12 - 8 Al AWG wire, 35 to 60 amp 8 - 3 Cu or 8 - 2 Al AWG wire. UL Listed, HACR rated. 1" module, 120/240 volt; 10,000 AIR.
GE THQL1115 Type THQL Q-Line Standard Circuit Breaker GE THQP130 Type THQP Q-Line Standard Circuit Breaker GE THQP120 Type THQP Q-Line Standard Circuit Breaker
Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Type THQL - 1" per pole. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger and Crouse-Hinds. 15 to 30 amp 14 - 8 Cu or 12 - 8 Al AWG wire, 35 to 60 amp 8 - 3 Cu or 8 - 2 Al AWG wire. UL Listed, HACR rated. 1" module, 120/240 volt; 10,000 AIR. Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space,  1/2" per pole. UL Listed, HACR rated. 15 and 20 amp SWD, switching duty rated, suitable for 120 volt fluorescent lighting loads. 15 to 25 amp #14 - 8 Cu or #12 - 8 Al AWG wire, 30 to 50 amp #8 - 4 Cu or #8 - 2 Al AWG wire. 3-9/32" height x 1/2" width x 2-3/8" depth. 120/240 volt; 10,000 AIR. Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space,  1/2" per pole. UL Listed, HACR rated. 15 and 20 amp SWD, switching duty rated, suitable for 120 volt fluorescent lighting loads. 15 to 25 amp #14 - 8 Cu or #12 - 8 Al AWG wire, 30 to 50 amp #8 - 4 Cu or #8 - 2 Al AWG wire. 3-9/32" height x 1/2" width x 2-3/8" depth. 120/240 volt; 10,000 AIR.
GE THQP115 Type THQP Q-Line Standard Circuit Breaker MES MP115 Type MP-T Circuit Breaker MES MP130 Type MP-T Circuit Breaker
Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space,  1/2" per pole. UL Listed, HACR rated. 15 and 20 amp SWD, switching duty rated, suitable for 120 volt fluorescent lighting loads. 15 to 25 amp #14 - 8 Cu or #12 - 8 Al AWG wire, 30 to 50 amp #8 - 4 Cu or #8 - 2 Al AWG wire. 3-9/32" height x 1/2" width x 2-3/8" depth. 120/240 volt; 10,000 AIR. One 1" space per pole. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (Full size only), General Switch, I-TE, Gould, Montgomery Ward and Sears. UL Listed, SWD rated. 120 volt AC fluorescent lighting. 120 volt AC; 10,000 AIR. One 1" space per pole. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (Full size only), General Switch, I-TE, Gould, Montgomery Ward and Sears. UL Listed, SWD rated. 120 volt AC fluorescent lighting. 120 volt AC; 10,000 AIR.
MES Q120 Standard Miniature Circuit Breaker MES Q130 Standard Miniature Circuit Breaker HomeLine HOM115C Miniature Standard Circuit Breaker
Non-interchangeable trip. 120 volt AC; 10,000 AIR. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (Full size only), General Switch, I-TE, Gould, Montgomery Ward and Sears. UL Listed, HACR rated. 15 and 20 amp UL Listed for frequent switching applications, 120 volt AC fluorescent lighting.  1" per pole. Non-interchangeable trip. 120 volt AC; 10,000 AIR. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (Full size only), General Switch, I-TE, Gould, Montgomery Ward and Sears. UL Listed, HACR rated. 15 and 20 amp UL Listed for frequent switching applications, 120 volt AC fluorescent lighting.  1" per pole. Single-pole 1" circuit breaker features 10,000 AIR and 120/240 VAC. Uses a thermal-magnetic tripping mechanism for overload and short-circuit protection. Compatible with Homeline load centers and CSED devices. ANSI certified and UL Listed.
HomeLine HOM130C Miniature Standard Circuit Breaker HomeLine HOM120C Miniature Standard Circuit Breaker MES MP120 Type MP-T Circuit Breaker
Single-pole 1" circuit breaker features 10,000 AIR and 120/240 VAC. Uses a thermal-magnetic tripping mechanism for overload and short-circuit protection. Compatible with Homeline load centers and CSED devices. ANSI certified and UL Listed. Single-pole 1" circuit breaker features 10,000 AIR and 120/240 VAC. Uses a thermal-magnetic tripping mechanism for overload and short-circuit protection. Compatible with Homeline load centers and CSED devices. ANSI certified and UL Listed. One 1" space per pole. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (Full size only), General Switch, I-TE, Gould, Montgomery Ward and Sears. UL Listed, SWD rated. 120 volt AC fluorescent lighting. 120 volt AC; 10,000 AIR.
Eaton BR130 Type BR Miniature Circuit Breaker Eaton BR140 Type BR Miniature Circuit Breaker Eaton BR150 Type BR Miniature Circuit Breaker
Switching duty rating. Thermal magnetic 40 degrees C. Interchangeable, will replace: Bryant, Westinghouse and Challenger. Type BR. 120/240 volt, 10,000 AIR. 1" per pole. Switching duty rating. Thermal magnetic 40 degrees C. Interchangeable, will replace: Bryant, Westinghouse and Challenger. Type BR. 120/240 volt, 10,000 AIR. 1" per pole. Switching duty rating. Thermal magnetic 40 degrees C. Interchangeable, will replace: Bryant, Westinghouse and Challenger. Type BR. 120/240 volt, 10,000 AIR. 1" per pole.
GE THQL1140 Type THQL Q-Line Standard Circuit Breaker GE THQL1150 Type THQL Q-Line Standard Circuit Breaker GE THQP150 Type THQP Q-Line Standard Circuit Breaker
Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Type THQL - 1" per pole. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger and Crouse-Hinds. 15 to 30 amp 14 - 8 Cu or 12 - 8 Al AWG wire, 35 to 60 amp 8 - 3 Cu or 8 - 2 Al AWG wire. UL Listed, HACR rated. 1" module, 120/240 volt; 10,000 AIR. Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Type THQL - 1" per pole. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger and Crouse-Hinds. 15 to 30 amp 14 - 8 Cu or 12 - 8 Al AWG wire, 35 to 60 amp 8 - 3 Cu or 8 - 2 Al AWG wire. UL Listed, HACR rated. 1" module, 120/240 volt; 10,000 AIR. Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space,  1/2" per pole. UL Listed, HACR rated. 15 and 20 amp SWD, switching duty rated, suitable for 120 volt fluorescent lighting loads. 15 to 25 amp #14 - 8 Cu or #12 - 8 Al AWG wire, 30 to 50 amp #8 - 4 Cu or #8 - 2 Al AWG wire. 3-9/32" height x 1/2" width x 2-3/8" depth. 120/240 volt; 10,000 AIR.
GE THQP140 Type THQP Q-Line Standard Circuit Breaker Eaton CL115 Type CL Circuit Breaker Eaton CL130 Type CL Circuit Breaker
Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space,  1/2" per pole. UL Listed, HACR rated. 15 and 20 amp SWD, switching duty rated, suitable for 120 volt fluorescent lighting loads. 15 to 25 amp #14 - 8 Cu or #12 - 8 Al AWG wire, 30 to 50 amp #8 - 4 Cu or #8 - 2 Al AWG wire. 3-9/32" height x 1/2" width x 2-3/8" depth. 120/240 volt; 10,000 AIR. Wire size range #14-4. Type CL replacement breakers, classified as direct replacements by Underwriters Laboratories for Square D HOMELINE, General Electric, Crouse-Hinds, Thomas & Betts, Murray and ITE/Siemens loadcenters. 120/240 volt AC, 10,000 AIC. Requires one 1-Inch (25.4 mm) space. Wire size range #14-4. Type CL replacement breakers, classified as direct replacements by Underwriters Laboratories for Square D HOMELINE, General Electric, Crouse-Hinds, Thomas & Betts, Murray and ITE/Siemens loadcenters. 120/240 volt AC, 10,000 AIC. Requires one 1-Inch (25.4 mm) space.
Eaton CL120 Type CL Circuit Breaker Eaton CH115 Type CH Circuit Breaker Eaton CH120 Type CH Circuit Breaker
Wire size range #14-4. Type CL replacement breakers, classified as direct replacements by Underwriters Laboratories for Square D HOMELINE, General Electric, Crouse-Hinds, Thomas & Betts, Murray and ITE/Siemens loadcenters. 120/240 volt AC, 10,000 AIC. Requires one 1-Inch (25.4 mm) space. Quick make, quick break switch, inverse time element tripping operation and trip free handle. Thermal-magnetic trip curve. UL Listed, HACR rated, meets NEMA standards and Federal Specifications, CSA certified. 120/240 volt AC. 10,000 AIR. 3/4" per pole. Quick make, quick break switch, inverse time element tripping operation and trip free handle. Thermal-magnetic trip curve. UL Listed, HACR rated, meets NEMA standards and Federal Specifications, CSA certified. 120/240 volt AC. 10,000 AIR. 3/4" per pole.
Eaton CH130 Type CH Miniature Circuit Breaker Eaton CH140 Type CH Circuit Breaker Square D QO140CP Type QO Standard Circuit Breaker
Quick make, quick break switch, inverse time element tripping operation and trip free handle. Thermal-magnetic trip curve. UL Listed, HACR rated, meets NEMA standards and Federal Specifications, CSA certified. 120/240 volt AC. 10,000 AIR. 3/4" per pole. Quick make, quick break switch, inverse time element tripping operation and trip free handle. Thermal-magnetic trip curve. UL Listed, HACR rated, meets NEMA standards and Federal Specifications, CSA certified. 120/240 volt AC. 10,000 AIR. 3/4" per pole. Single-pole 3/4" circuit breaker provides overload and short circuit protection. Features a red Visi-Trip indicator to identify a tripped breaker. Accepts aluminum or copper conductors. Rated for 120/240Vac and at 10,000 Ampre Interrupting Rating (AIR). CSA approved to only install in Canadian Square D loadcentres.
Square D QO150CP Type QO Standard Circuit Breaker Square D QO115CP Type QO Standard Circuit Breaker Square D QO120CP Type QO Standard Circuit Breaker
Single-pole 3/4" circuit breaker provides overload and short circuit protection. Features a red Visi-Trip indicator to identify a tripped breaker. Accepts aluminum or copper conductors. Rated for 120/240Vac and at 10,000 Ampre Interrupting Rating (AIR). CSA approved to only install in Canadian Square D loadcentres. Single-pole 3/4" circuit breaker provides overload and short circuit protection. Features a red Visi-Trip indicator to identify a tripped breaker. Accepts aluminum or copper conductors. Rated for 120/240Vac and at 10,000 Ampre Interrupting Rating (AIR). CSA approved to only install in Canadian Square D loadcentres. Single-pole 3/4" circuit breaker provides overload and short circuit protection. Features a red Visi-Trip indicator to identify a tripped breaker. Accepts aluminum or copper conductors. Rated for 120/240Vac and at 10,000 Ampre Interrupting Rating (AIR). CSA approved to only install in Canadian Square D loadcentres.
Square D QO130CP Type QO Standard Circuit Breaker Square D QO115C Miniature Standard Circuit Breaker Square D QO120C Miniature Standard Circuit Breaker
Single-pole 3/4" circuit breaker provides overload and short circuit protection. Features a red Visi-Trip indicator to identify a tripped breaker. Accepts aluminum or copper conductors. Rated for 120/240Vac and at 10,000 Ampre Interrupting Rating (AIR). CSA approved to only install in Canadian Square D loadcentres. Single-pole 3/4" circuit breaker provides overload and short circuit protection. Features a red Visi-Trip indicator to identify a tripped breaker. Accepts aluminum or copper conductors. Rated for 120/240Vac and at 10,000 Ampre Interrupting Rating (AIR). CSA approved to only install in Canadian Square D loadcentres. Single-pole 3/4" circuit breaker provides overload and short circuit protection. Features a red Visi-Trip indicator to identify a tripped breaker. Accepts aluminum or copper conductors. Rated for 120/240Vac and at 10,000 Ampre Interrupting Rating (AIR). CSA approved to only install in Canadian Square D loadcentres.
Square D QO130C Miniature Standard Circuit Breaker HomeLine HOMT2020CP Tandem Twin Circuit Breaker HomeLine HOMT1515CP Tandem Circuit Breaker
Single-pole 3/4" circuit breaker provides overload and short circuit protection. Features a red Visi-Trip indicator to identify a tripped breaker. Accepts aluminum or copper conductors. Rated for 120/240Vac and at 10,000 Ampre Interrupting Rating (AIR). CSA approved to only install in Canadian Square D loadcentres. Tandem 1" single-pole circuit breaker. Offers 2 circuits in the space of 1. Features 10,000 AIR and 120/240 VAC. Thermal-magnetic tripping mechanism for overload and short-circuit protection of the electrical system. Accepts aluminum or copper conductors. CSA approved to only install in Canadian HomeLine loadcentres. Tandem 1" single-pole circuit breaker. Offers 2 circuits in the space of 1. Features 10,000 AIR and 120/240 VAC. Thermal-magnetic tripping mechanism for overload and short-circuit protection of the electrical system. Accepts aluminum or copper conductors. CSA approved to only install in Canadian HomeLine loadcentres.
Eaton BD2020 Type BD Twin Circuit Breaker Eaton BD2030 Type BD Twin Circuit Breaker Eaton BD1515 Type BD Twin Circuit Breaker
Switching duty rating, Duplex type breaker requires 1" per breaker. Thermal magnetic 40 degrees C breakers have rejection tab feature, allows only 42 circuits in the panel in compliance with NEC article 384-15. Interchangeable will replace: Bryant, Challenger and Westinghouse. Type BR. 120/240 volt. 10,000 AIR. 1" per breaker. Switching duty rating, Duplex type breaker requires 1" per breaker. Thermal magnetic 40 degrees C breakers have rejection tab feature, allows only 42 circuits in the panel in compliance with NEC article 384-15. Interchangeable will replace: Bryant, Challenger and Westinghouse. Type BR. 120/240 volt. 10,000 AIR. 1" per breaker. Switching duty rating, Duplex type breaker requires 1" per breaker. Thermal magnetic 40 degrees C breakers have rejection tab feature, allows only 42 circuits in the panel in compliance with NEC article 384-15. Interchangeable will replace: Bryant, Challenger and Westinghouse. Type BR. 120/240 volt. 10,000 AIR. 1" per breaker.
Cutler Hammer CH115CS Miniature Standard Type CH Circuit Breaker Cutler Hammer CH130CS Miniature Standard Type CH Circuit Breaker Cutler Hammer CH120CS Miniature Standard Type CH Circuit Breaker
Quick make, quick break switch, inverse time element tripping operation and trip free handle. Thermal-magnetic trip curve. UL Listed, HACR rated, meets NEMA standards and Federal Specifications, CSA certified. 120/240 volt AC. 10,000 AIR. 3/4" per pole. Quick make, quick break switch, inverse time element tripping operation and trip free handle. Thermal-magnetic trip curve. UL Listed, HACR rated, meets NEMA standards and Federal Specifications, CSA certified. 120/240 volt AC. 10,000 AIR. 3/4" per pole. Quick make, quick break switch, inverse time element tripping operation and trip free handle. Thermal-magnetic trip curve. UL Listed, HACR rated, meets NEMA standards and Federal Specifications, CSA certified. 120/240 volt AC. 10,000 AIR. 3/4" per pole.
MES MP1515 Type MP-T Duplex NCL Tandem Circuit Breaker MES Q1515 Twin Miniature Circuit Breaker MES Q2020 Twin Miniature Circuit Breaker
Complete, unenclosed, molded case breaker with non-interchangeable trip. Takes the place of 2 single pole breakers in 1" of space. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (full size only), General Switch, I-T-E, Gould, Montgomery Ward and Sears. HACR and SWD rated. UL listed and CSA certified. 120 volt AC; 10,000 AIR. Complete, unenclosed, molded case breaker with non-interchangeable trip. Takes the place of 2 single pole breakers in 1" of space. Wire range: CU fron #14 to # 8, AI from #12 to #6. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (full size only), General Switch, I-T-E, Gould, Montgomery Ward and Sears. HACR rated. 120/240 volt AC; 10,000 AIR. Complete, unenclosed, molded case breaker with non-interchangeable trip. Takes the place of 2 single pole breakers in 1" of space. Wire range: CU fron #14 to # 8, AI from #12 to #6. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (full size only), General Switch, I-T-E, Gould, Montgomery Ward and Sears. HACR rated. 120/240 volt AC; 10,000 AIR.
MES MP2020 Type MP-T Duplex Tandem Circuit Breaker Connecticut ICBQ Interchangeable Carded Type QP Circuit Breaker Connecticut ICBQ Interchangeable Carded Type QP Circuit Breaker
Complete, unenclosed, molded case breaker with non-interchangeable trip. Takes the place of 2 single pole breakers in 1" of space. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (full size only), General Switch, I-T-E, Gould, Montgomery Ward and Sears. HACR and SWD rated. UL listed and CSA certified. 120 volt AC; 10,000 AIR. Interchangeable group will fit most General Electric, General Switch, ITE, Murray, American Switch, Westinghouse Type BR and Bryant. ITE/SIEMENS. 120 volt AC, 10,000 AIC. Interchangeable group will fit most General Electric, General Switch, ITE, Murray, American Switch, Westinghouse Type BR and Bryant. ITE/SIEMENS. 120 volt AC, 10,000 AIC.
Connecticut ICBQ Interchangeable Carded Type QP Circuit Breaker Eaton BR2020 Type BR Duplex Miniature Circuit Breaker Eaton BR1515 Type BR Duplex Miniature Circuit Breaker
Interchangeable group will fit most General Electric, General Switch, ITE, Murray, American Switch, Westinghouse Type BR and Bryant. ITE/SIEMENS. 120 volt AC, 10,000 AIC. Non-circuit limiting, less rejection tabs. 120 volt AC, 10,000 AIC. 1 space per pole. Non-circuit limiting, less rejection tabs. 120 volt AC, 10,000 AIC. 1 space per pole.
Eaton BR3030 Type BR Miniature Circuit Breaker Square D QOT1515CP Type QO Tandem Circuit Breaker Square D QOT2020CP Type QO Tandem Circuit Breaker
Non-circuit limiting, less rejection tabs. 120 volt AC, 10,000 AIC. 1 space per pole. Single-pole 3/4" circuit breaker offers 2 circuits in the space of 1 for overload and short-circuit protection of an electrical system. Use with QO load centers and CSED devices. ANSI certified and UL Listed. Single-pole 3/4" circuit breaker offers 2 circuits in the space of 1 for overload and short-circuit protection of an electrical system. Use with QO load centers and CSED devices. ANSI certified and UL Listed.
Cutler Hammer CHT2020CS Miniature Twin Type CHT Circuit Breaker MES Q2020NC Non-CTL Twin Miniature Circuit Breaker Connecticut UBIP120 Type UBIP Standard Circuit Breaker
Single-pole, twin (CTL) 3/4-inch (19.1 mm) per pole, requires one 3/4-inch (19.1 mm) space. Wire size range Cu/Al 60 degrees C or 75 degrees C number 14-8. Class CTL 10 kAIC. Rejection feature. Use only with loadcenters marked for use with CHT breakers. HACR and switching duty rated. Rated for 120/240V. Non-interchangeable trip. For retrofit use on I-T-E load centers built prior to 1965. 120/240 volt AC. 1" per duplex. For ITE Pushmatic load centers. 1.5" space per breaker. SWD rated. 120 volt AC, 10,000 AIC.
Connecticut UBIP130 Type UBIP Standard Circuit Breaker Connecticut ICBQ Interchangeable Carded Type QP Circuit Breaker Connecticut ICBQ Interchangeable Carded Type QP Circuit Breaker
For ITE Pushmatic load centers. 1.5" space per breaker. SWD rated. 120 volt AC, 10,000 AIC. Interchangeable group will fit most General Electric, General Switch, ITE, Murray, American Switch, Westinghouse Type BR and Bryant. Twin pole, 1" space per breaker. Interchangeable group will fit most General Electric, General Switch, ITE, Murray, American Switch, Westinghouse Type BR and Bryant. Twin pole, 1" space per breaker.
Connecticut UBIF Standard Thin Type NC Circuit Breaker Connecticut UBIF Standard Thin Type NC Circuit Breaker Connecticut UBIF Standard Thin Type NC Circuit Breaker
For Federal Pacific Load Centers. SWD/HACR Rated. 120/240 volt AC, 10,000 AIC. For Federal Pacific Load Centers. SWD/HACR Rated. 120/240 volt AC, 10,000 AIC. For Federal Pacific Load Centers. SWD/HACR Rated. 120/240 volt AC, 10,000 AIC.
Connecticut UBIF Standard Thick Type NA Circuit Breaker Connecticut UBIF Standard Thick Type NA Circuit Breaker Connecticut UBIF Standard Thick Type NA Circuit Breaker
Replacement for Federal Pacific Load Centers. Single pole SWD rated, double pole is HACR rated. 120/240 volt AC, 10,000 AIC. Replacement for Federal Pacific Load Centers. Single pole SWD rated, double pole is HACR rated. 120/240 volt AC, 10,000 AIC. Replacement for Federal Pacific Load Centers. Single pole SWD rated, double pole is HACR rated. 120/240 volt AC, 10,000 AIC.
Connecticut UBIZ20 Type UBIZ Thick Circuit Breaker Connecticut UBIZ Standard Thick Circuit Breaker Connecticut UBIP2020 Type UBIP Tandem Twin Circuit Breaker
Replacement for Zinsco Q series. Requires one 3/4" space. HACR-(heating and air conditioning) rated. Tested and certified in accordance with the National Electric Code and conforms to the ANSI/UL Standard 489, 9th Edition. 120 volt AC - 10,000 AIC. Carded. Replacement for Zinsco Q series. Requires one 3/4" space. HACR-(heating and air conditioning) rated. Tested and certified in accordance with the National Electric Code and conforms to the ANSI/UL Standard 489, 9th Edition. 120 volt AC - 10,000 AIC. Carded. For Pushmatic load centers. SWD Rated. 120 volt AC, 10,000 AIC. 1.5" space per breaker.
BREAKER 15A1P 120V DUAL FUNCTN BREAKER 20A1P 120V DUAL FUNCTN Square D QO1515CP Type QO Tandem Circuit Breaker
Detects when current is "leaking" somewhere outside its intended path. Should the DFCI trip, the yellow LED Indicates the last known trip condition by illuminating LED for 5 seconds each time the DFCI is turned on for up to 30 days. Self-test feature. UL Listed. 3.3" height x 1" width x 3" depth, .479 lb. Detects when current is "leaking" somewhere outside its intended path. Should the DFCI trip, the yellow LED Indicates the last known trip condition by illuminating LED for 5 seconds each time the DFCI is turned on for up to 30 days. Self-test feature. UL Listed. 3.3" height x 1" width x 3" depth, .479 lb. Single-pole 3/4" circuit breaker provides overload and short circuit protection with 2 independent trip poles to give 2 circuits in the space of 1 breaker. Features a red Visi-Trip indicator to identify a tripped breaker. Accepts aluminum or copper conductors. Rated for 120/240VAC and at 10,000 Ampre Interrupting Rating (AIR). CSA approved.
Square D QO2020CP Type QO Replacement Tandem Circuit Breaker
Single-pole 3/4" circuit breaker provides overload and short circuit protection with 2 independent trip poles to give 2 circuits in the space of 1 breaker. Features a red Visi-Trip indicator to identify a tripped breaker. Accepts aluminum or copper conductors. Rated for 120/240VAC and at 10,000 Ampre Interrupting Rating (AIR). CSA approved.
   
 
1