Home > ELECTRICAL > ROUGH ELECTRICAL > ELECTRICAL FITTINGS
Sort By:
1 2 3 4
Carlon E940D-CTN Standard Conduit Coupling Halex 71205B 2-Hole Conduit Strap Carlon E940E-CTN/CAR Standard Conduit Coupling
Safe, non-conductive. Schedule 40 non-metallic socket type coupling for joining Schedule 40 non-metallic conduit. Will not rust or corrode. RoHS Compliance, UL Listed. Indoor or outdoor applications. Use to secure PVC conduit to wood, masonry or similar surface. Bulk packed. Safe, non-conductive. Schedule 40 non-metallic socket type coupling for joining Schedule 40 non-metallic conduit. Will not rust or corrode. RoHS Compliance, UL Listed.
Carlon E942DR-CTN Conduit Adapter Carlon E943D-CTN Terminal Adapter Carlon E942ER-CTN Conduit Adapter
Safe, non-conductive. For adapting Schedule 40 non-metallic conduit to boxes, threaded fittings, metallic systems. Female threads one end, socket end on the other. Will not rust or corrode. Safe, non-conductive. For adapting schedule 40 non-metallic conduit to boxes, threaded fittings, metallic systems. Male threads on one end, socket end on the other. Will not rust or corrode. UL Listed, RoHS Compliance. Safe, non-conductive. For adapting Schedule 40 non-metallic conduit to boxes, threaded fittings, metallic systems. Female threads one end, socket end on the other. Will not rust or corrode.
Carlon E943E-CTN Terminal Adapter Halex 61612B 2-Hole Snap-On Conduit Strap Carlon E940FR-CTN Standard Conduit Coupling
Safe, non-conductive. For adapting schedule 40 non-metallic conduit to boxes, threaded fittings, metallic systems. Male threads on one end, socket end on the other. Will not rust or corrode. UL Listed, RoHS Compliance. To support EMT conduit where greater load bearing is required. Indoor or outdoor applications. Safe, non-conductive. Schedule 40 non-metallic socket type coupling for joining Schedule 40 non-metallic conduit. Will not rust or corrode. RoHS Compliance, UL Listed.
1/2 RIGID CONDUIT LOCKNUT 3/4 PLAST INSULATED BUSHING Halex 71210B 2-Hole Conduit Strap
1/2 RIGID CONDUIT LOCKNUT
Our Price : $0.59
Steel with zinc plating. Indoor or outdoor applications. Use to secure Rigid or IMC conduit or various threaded fittings to a steel outlet box or other metal enclosure. High impact thermoplastic. Flame retardant to 105 degrees C. Use with locknut to terminate threaded Rigid or IMC conduit to an outlet box. The rounded surface of the bushing prevents damage to wire insulation. Required by the NEC. UL Listed, CSA Approved. Indoor or outdoor applications. Use to secure PVC conduit to wood, masonry or similar surface. Bulk packed.
Halex 71212B 2-Hole Conduit Strap Carlon E996DR-CTN Conduit Box Adapter Carlon E943FR-CTN Terminal Adapter
Indoor or outdoor applications. Use to secure PVC conduit to wood, masonry or similar surface. Bulk packed. For PVC enclosures. cULus Listed. Safe, non-conductive. For adapting schedule 40 non-metallic conduit to boxes, threaded fittings, metallic systems. Male threads on one end, socket end on the other. Will not rust or corrode. UL Listed, RoHS Compliance.
Carlon Snap Strap E978EC-CAR 1-Hole Single Conduit Strap Carlon Snap Strap E978DC-CAR 1-Hole Single Conduit Strap Carlon UA9ADB-CTN Standard Radius Rigid Conduit Elbow
Safe, non-conductive. To be used in accordance with NEC, Article 347.8 conduit spacing requirements. For use with Schedule 40/80 non-metallic solvent weld fittings. Safe, non-conductive. To be used in accordance with NEC, Article 347.8 conduit spacing requirements. For use with Schedule 40/80 non-metallic solvent weld fittings. For use with nonmetallic solvent weld fittings. Nonconductive, impact, corrosion and sunlight resistant. Schedule 40. UL 651 Listed to the NEC by the ETL, UL Listed.
Halex 96163 2-Hole Snap-On Conduit Strap 3/8IN FLEX-BX SCRWIN CONNECTOR 3/4 RIGID CONDUIT LOCKNUT
3/4 RIGID CONDUIT LOCKNUT
Our Price : $0.69
To support EMT conduit where greater load bearing is required. Indoor or outdoor applications. Zinc die cast. Use to connect flexible metallic conduit (Greenfield) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. Steel with zinc plating. Indoor or outdoor applications. Use to secure Rigid or IMC conduit or various threaded fittings to a steel outlet box or other metal enclosure.
1/2 PLAST INSULATED BUSHING Halex 71215B 2-Hole Conduit Strap 1-1/2 PLAST INSULATING BUSHING
High impact thermoplastic. Flame retardant to 105 degrees C. Use with locknut to terminate threaded Rigid or IMC conduit to an outlet box. The rounded surface of the bushing prevents damage to wire insulation. Required by the NEC. UL Listed, CSA Approved. Indoor or outdoor applications. Use to secure PVC conduit to wood, masonry or similar surface. Bulk packed. High impact thermoplastic. Flame retardant to 105 degrees C. Use with locknut to terminate threaded Rigid or IMC conduit to an outlet box. The rounded surface of the bushing prevents damage to wire insulation. Required by the NEC. UL Listed, CSA Approved.
Carlon E996ER-CTN Conduit Box Adapter Carlon UA9ADR-CTN Standard Radius Conduit Elbow Carlon E940GR-CTN Standard Conduit Coupling
For PVC enclosures. cULus Listed. For use with nonmetallic solvent weld fittings. Nonconductive, impact, corrosion and sunlight resistant. Safe, non-conductive. Schedule 40 non-metallic socket type coupling for joining Schedule 40 non-metallic conduit. Will not rust or corrode. RoHS Compliance, UL Listed.
Carlon E940HR-CTN Standard Conduit Coupling Carlon E942FR-CTN Conduit Adapter Carlon E943GR-CTN Terminal Adapter
Safe, non-conductive. Schedule 40 non-metallic socket type coupling for joining Schedule 40 non-metallic conduit. Will not rust or corrode. RoHS Compliance, UL Listed. Safe, non-conductive. For adapting Schedule 40 non-metallic conduit to boxes, threaded fittings, metallic systems. Female threads one end, socket end on the other. Will not rust or corrode. Safe, non-conductive. For adapting schedule 40 non-metallic conduit to boxes, threaded fittings, metallic systems. Male threads on one end, socket end on the other. Will not rust or corrode. UL Listed, RoHS Compliance.
3/8 NM/SE CLAMP CONNECTOR Halex 96111 1-Hole Conduit Strap 1/2IN KNOCKOUT SEAL BAGGED
3/8 NM/SE CLAMP CONNECTOR
Our Price : $0.79
Fits 1/2" knockout, non-metallic cable numbers 14/2, 12/2, 12/3 AWG or 2 number 14/2 AWG or flex cord .300 to .560 inches diameter. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL, Listed, me Indoor or outdoor applications. Use to secure Rigid or I.M.C. conduit to wood, masonry or similar surfaces. Use to cover exposed knock-out holes in steel outlet boxes and other metal enclosures.
3/4IN KNOCKOUT SEAL BAGGED Carlon UA7ADB-CTN Standard Radius Conduit Elbow Carlon A240D-CAR 1-Piece Conduit Coupling
Use to cover exposed knock-out holes in steel outlet boxes and other metal enclosures. For use with nonmetallic solvent weld fittings. Nonconductive, impact, corrosion and sunlight resistant. UL Listed E35297. Quick connect, fold and snap together. No cement, set screws or lock nuts. For 600 volt use in ceilings, floors and walls in residential, commercial and industrial buildings not more than three floors above grade. Colored in brilliant electric blue. For indoor use. Concrete tight when used with Carlon ENT. UL Listed.
Halex 96821 Rigid Reducing Conduit Washer Carlon UA9AEB-CTN Standard Radius Rigid Conduit Elbow Halex 96560 Beam Clamp
Use to reduce the size of the conduit hole knockout opening in a steel outlet box or other metal enclosure. Must use one inside the enclosure opening and one on the outside. UL Listed, CSA Approved. For use with nonmetallic solvent weld fittings. Nonconductive, impact, corrosion and sunlight resistant. Schedule 40. UL 651 Listed to the NEC by the ETL, UL Listed. Use to secure conduit to a metal beam. Clamps on beam, girder or similar structure to provide a mounting base for attachment of a conduit hanger, either directly or by means of a threaded rod. Eliminates need to drill hole through beam.
1IN PLAST INSULATING BUSHING Carlon UA9AER-CTN Standard Radius Conduit Elbow 1" CONDUIT LOCKNUT STEEL 2/BG
High impact thermoplastic. Flame retardant to 105 degrees C. Use with locknut to terminate threaded Rigid or IMC conduit to an outlet box. The rounded surface of the bushing prevents damage to wire insulation. Required by the NEC. UL Listed, CSA Approved. For use with nonmetallic solvent weld fittings. Nonconductive, impact, corrosion and sunlight resistant. Steel with zinc plating. Indoor or outdoor applications. Use to secure Rigid or IMC conduit or various threaded fittings to a steel outlet box or other metal enclosure.
1/2" EMT SETSCREW CONNECTOR 1/2IN FLEX-BX SCRWIN COUPLING Halex 96831 Rigid Reducing Conduit Washer
Zinc die cast. Use to connect EMT conduit to steel outlet box, load center or other metal enclosure. UL Approved. Zinc die cast. Use to join two pieces of flexible metallic conduit (Greenfield) together. Use to reduce the size of the conduit hole knockout opening in a steel outlet box or other metal enclosure. Must use one inside the enclosure opening and one on the outside. UL Listed, CSA Approved.
Halex 96832 Rigid Reducing Conduit Washer Halex 26190 Conduit Locknut 1/2IN NM FLEX-EMT COMB COUPL
Use to reduce the size of the conduit hole knockout opening in a steel outlet box or other metal enclosure. Must use one inside the enclosure opening and one on the outside. UL Listed, CSA Approved. Halex Conduit Locknut, 1/2 in Nominal, Steel, Zinc Plated, CSA Certified, UL Listed, For use to secure rigid, imc conduit or various threaded fittings to a steel outlet box or other metal enclosure, indoor/outdoor Zinc die cast. Use to join EMT conduit to non-metallic sheathed cable. #14/2, #12/3 or 2 #14/2. Indoor use only. With UPC. UL Approved.
Halex 61220B 2-Hole Conduit Strap Halex 71220B 2-Hole Conduit Strap Carlon A253D-CAR 1-Piece Snap-In Terminal Adapter
Indoor or outdoor use. Use to secure Rigid or IMC conduit to wood, masonry or similar surfaces where greater load bearing is required. UL Listed, CSA Approved. Indoor or outdoor applications. Use to secure PVC conduit to wood, masonry or similar surface. Bulk packed. Fold and snap together. No cement, set screws or lock nuts. For 600 volt use in ceilings, floors and walls in residential, commercial and industrial buildings not more than three floors above grade. Colored in brilliant electric blue. For indoor use. Concrete tight when used with Carlon ENT. UL Listed.
Carlon A253E-CAR 1-Piece Snap-In Terminal Adapter 1-1/4 PLAST INSULATING BUSHING Carlon UA7ADR-CAR Standard Radius Conduit Elbow
Fold and snap together. No cement, set screws or lock nuts. For 600 volt use in ceilings, floors and walls in residential, commercial and industrial buildings not more than three floors above grade. Colored in brilliant electric blue. For indoor use. Concrete tight when used with Carlon ENT. UL Listed. High impact thermoplastic. Flame retardant to 105 degrees C. Use with locknut to terminate threaded Rigid or IMC conduit to an outlet box. The rounded surface of the bushing prevents damage to wire insulation. Required by the NEC. UL Listed, CSA Approved. For use with nonmetallic solvent weld fittings. Nonconductive, impact, corrosion and sunlight resistant. UL Listed E35297.
Carlon UA7AER-CAR Standard Radius Conduit Elbow Carlon E940JR-CTN Standard Conduit Coupling Carlon E942GR-CTN Conduit Adapter
For use with nonmetallic solvent weld fittings. Nonconductive, impact, corrosion and sunlight resistant. UL Listed E35297. Safe, non-conductive. Schedule 40 non-metallic socket type coupling for joining Schedule 40 non-metallic conduit. Will not rust or corrode. RoHS Compliance, UL Listed. Safe, non-conductive. For adapting Schedule 40 non-metallic conduit to boxes, threaded fittings, metallic systems. Female threads one end, socket end on the other. Will not rust or corrode.
Carlon E942HR Conduit Adapter Carlon E943HR-CTN Terminal Adapter Thomas & Betts E977DC-CTN 2-Hole Conduit Clamp
Safe, non-conductive. For adapting Schedule 40 non-metallic conduit to boxes, threaded fittings, metallic systems. Female threads one end, socket end on the other. Will not rust or corrode. Safe, non-conductive. For adapting schedule 40 non-metallic conduit to boxes, threaded fittings, metallic systems. Male threads on one end, socket end on the other. Will not rust or corrode. UL Listed, RoHS Compliance. Offers same chemical resistance as Carlon nonmetallic conduit for a complete, corrosion resistant system. UV resistant for use in direct sunlight. Use in accordance with conduit spacing requirements per NEC. Each clamp requires 2 screws, 2 nuts, and 2 washers. Gray clamps for standard conduit.
Carlon Snap Strap E978FC-CAR 1-Hole Single Conduit Strap Thomas & Betts E950ED-CTN Reducing Bushing Carlon A243D-CAR 1-Piece Snap-In Conduit Adapter
Safe, non-conductive. To be used in accordance with NEC, Article 347.8 conduit spacing requirements. For use with Schedule 40/80 non-metallic solvent weld fittings. For connecting different sizes of conduit. Socket both ends, for reducing male Schedule 40/80 conduit runs or fittings to female. Non-conductive. Will not rust or corrode. Innovative one piece quick connect design for fast and easy installation. Suitable for damp locations. No glue or cement needed. Carlon Standard Blue. Concrete tight when used with appropriate ENT.
1/2IN EMT SETSCREW COUPLING 1/2IN FLEX-BX SCRWIN CONNECTOR 3/8 FLEX-BX CABLE CONNECTOR
Zinc die cast. Use to join two lengths of EMT conduit together. UL Approved. Zinc die cast. Use to connect flexible metallic conduit (Greenfield) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. Zinc die cast. In a dry location, use to connect BX cable to a steel outlet box or other metal enclosure. 3/8" size fits 1/2" knock outs. UL Approved.
1/2 RIGID CONDUIT CHASE NIPPLE Halex 96121 2-Hole Conduit Strap 3/4X1/2 RIGID REDUCING BUSHING
Zinc die cast. Indoor or outdoor applications. Use to terminate threaded conduit to a knockout box or enclosure, where space within the box is limited. Used with a locknut to provide a short raceway between boxes or enclosures. UL and CSA approved. Indoor or outdoor use. Use to secure Rigid or IMC conduit to wood, masonry or similar surfaces where greater load bearing is required. UL Listed, CSA Approved. Zinc die cast. Indoor or outdoor applications. Use to reduce the entry size of a run of threaded conduit. UL Approved.
Carlon UA7AEB-CTN Standard Radius Conduit Elbow 1/2 RGD&IMC BOX SPACER ZINC 1 1/4" LOCKNUT STEEL 2/BG
1 1/4" LOCKNUT STEEL 2/BG
Our Price : $1.19
For use with nonmetallic solvent weld fittings. Nonconductive, impact, corrosion and sunlight resistant. UL Listed E35297. Die cast of high strength corrosion resistant zinc alloy. Locknut is reversible. It is designed to cut through protective coatings on boxes and enclosures to assure ground continuity. Use as a raceway between two steel outlet boxes or other metal enclosur Steel with zinc plating. Indoor or outdoor applications. Use to secure Rigid or IMC conduit or various threaded fittings to a steel outlet box or other metal enclosure.
Carlon E943JRR Terminal Adapter Thomas & Betts E977EC-CTN 2-Hole Conduit Clamp Halex 96780 Conduit Hanger
Safe, non-conductive. For adapting schedule 40 non-metallic conduit to boxes, threaded fittings, metallic systems. Male threads on one end, socket end on the other. Will not rust or corrode. UL Listed, RoHS Compliance. Offers same chemical resistance as Carlon nonmetallic conduit for a complete, corrosion resistant system. UV resistant for use in direct sunlight. Use in accordance with conduit spacing requirements per NEC. Each clamp requires 2 screws, 2 nuts, and 2 washers. Gray clamps for standard conduit. Use to secure and suspend conduit from overhead supports. Comes with a nut and bolt.
3/4" EMT SETSCREW CONNECTOR Halex 96151 1-Hole Snap-On Conduit Strap Halex 96161 2-Hole Snap-On Conduit Strap
Zinc die cast. Use to connect EMT conduit to steel outlet box, load center or other metal enclosure. UL Approved. Indoor or outdoor applications. To support EMT conduit. To support EMT conduit where greater load bearing is required. Indoor or outdoor applications.
Halex 96112 1-Hole Conduit Strap WASHER RDUCNG RGD 1-1/4X1/2IN WASHER RDUCNG RGD 1-1/4X3/4IN
Indoor or outdoor applications. Use to secure Rigid or I.M.C. conduit to wood, masonry or similar surfaces. Use to reduce the size of the conduit hole knockout opening in a steel outlet box or other metal enclosure. Must use one inside the enclosure opening and one on the outside. UL Listed, CSA Approved. Use to reduce the size of the conduit hole knockout opening in a steel outlet box or other metal enclosure. Must use one inside the enclosure opening and one on the outside. UL Listed, CSA Approved.
Carlon A240E-CAR 1-Piece Conduit Coupling Carlon A243E-CAR 1-Piece Snap-In Conduit Adapter Carlon UA9AFB-CTN Standard Radius Conduit Elbow
Quick connect, fold and snap together. No cement, set screws or lock nuts. For 600 volt use in ceilings, floors and walls in residential, commercial and industrial buildings not more than three floors above grade. Colored in brilliant electric blue. For indoor use. Concrete tight when used with Carlon ENT. UL Listed. Innovative one piece quick connect design for fast and easy installation. Suitable for damp locations. No glue or cement needed. Carlon Standard Blue. Concrete tight when used with appropriate ENT. For use with nonmetallic solvent weld fittings. Nonconductive, impact, corrosion and sunlight resistant. Schedule 40. UL 651 Listed to the NEC by the ETL, UL Listed.
Carlon UA9AFR-CTN Standard Radius Conduit Elbow Carlon E942JR Conduit Adapter Carlon UA7AFR-CAR Standard Radius Conduit Elbow
For use with nonmetallic solvent weld fittings. Nonconductive, impact, corrosion and sunlight resistant. Safe, non-conductive. For adapting Schedule 40 non-metallic conduit to boxes, threaded fittings, metallic systems. Female threads one end, socket end on the other. Will not rust or corrode. For use with nonmetallic solvent weld fittings. Nonconductive, impact, corrosion and sunlight resistant. UL Listed E35297.
3/4IN EMT SETSCREW COUPLING 3/8 FLEX-BX CLAMP CONNECTOR Halex 96213 1-Hole Cable Strap
Zinc die cast. Use to join two lengths of EMT conduit together. UL Approved. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield, BX, NM or Metal Clad) to a steel outlet box or other metal enclosure. 3/8" size fits 1/2" knock outs. UL Approved. Steel, use to secure BX cable to wood, masonry or similar surface.
3/8 NM CLAMP CONNECTOR 2PC Halex 96122 2-Hole Conduit Strap 1X1/2 RIGID REDUCING BUSHING
Zinc die cast. In a dry location, use to secure #14 - #10 non-metallic sheathed cable to steel outlet box or other metal enclosure. No locknut required. Indoor or outdoor use. Use to secure Rigid or IMC conduit to wood, masonry or similar surfaces where greater load bearing is required. UL Listed, CSA Approved. Zinc die cast. Indoor or outdoor applications. Use to reduce the entry size of a run of threaded conduit. UL Approved.
1X3/4 RIGID REDUCING BUSHING Halex 96781 Conduit Hanger WASHER RDUCNG RGD 1-1/2X1/2IN
Zinc die cast. Indoor or outdoor applications. Use to reduce the entry size of a run of threaded conduit. UL Approved. Use to secure and suspend conduit from overhead supports. Comes with a nut and bolt. Use to reduce the size of the conduit hole knockout opening in a steel outlet box or other metal enclosure. Must use one inside the enclosure opening and one on the outside. UL Listed, CSA Approved.
WASHER RDUCING RGD 1-1/2X3/4IN 1IN EMT SET SCREW CONNECTOR Halex 96162 2-Hole Snap-On Conduit Strap
Use to reduce the size of the conduit hole knockout opening in a steel outlet box or other metal enclosure. Must use one inside the enclosure opening and one on the outside. UL Listed, CSA Approved. Zinc die cast. Use to connect EMT conduit to steel outlet box, load center or other metal enclosure. UL Approved. To support EMT conduit where greater load bearing is required. Indoor or outdoor applications.
3/4IN FLEX-BX SCRWIN CONNECTOR 3/8IN FLEX-BX 90DEG CONNECTOR 3/4 NM/SE CLAMP CONNECTOR
3/4 NM/SE CLAMP CONNECTOR
Our Price : $1.49
Zinc die cast. Use to connect flexible metallic conduit (Greenfield) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure. 3/8" size fits 1/2" knock outs. Fits non metallic cable, such as Romex, number 14/2 round, number 12/3-8/3 AWG or flex cord .460 to .720 inches diameter. With a 1/2" knockout. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL
1/2 RIGID BOX SPACER 1 1/2" LOCKNUT STEEL 2/BG 1/2IN KNOCKOUT SEAL
1/2 RIGID BOX SPACER
Our Price : $1.69
1 1/2" LOCKNUT STEEL 2/BG
Our Price : $1.69
1/2IN KNOCKOUT SEAL
Our Price : $1.69
Zinc die cast. Use as a raceway between two steel outlet boxes or other metal enclosures. UL Listed. Bulk packed. Steel with zinc plating. Indoor or outdoor applications. Use to secure Rigid or IMC conduit or various threaded fittings to a steel outlet box or other metal enclosure. Use to cover exposed knock-out holes in steel outlet boxes and other metal enclosures.
3/8IN NM CLAMP CONNECTOR Carlon E950FD-CAR Reducing Conduit Bushing Thomas & Betts E994DR-CTN Conduit Offset
3/8IN NM CLAMP CONNECTOR
Our Price : $1.69
Fits 1/2" knockout, non-metallic cable numbers 14/2, 12/2, 12/3 AWG or 2 number 14/2 AWG or flex cord .300 to .560 inches diameter. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL, Listed, me For connecting different sizes of conduit. Socket both ends, for reducing male Schedule 40/80 conduit runs or fittings to female. Non-conductive. Will not rust or corrode. Non-conductive. Will not rust or corrode.
1IN EMT SET SCREW COUPLING 1/2 ANTI-SHORT BUSHING Carlon E940K-CTN Conduit Coupling
1/2 ANTI-SHORT BUSHING
Our Price : $1.69
Zinc die cast. Use to join two lengths of EMT conduit together. UL Approved. High dielectric plastic. Use to protect wire within flexible metallic conduit (Greenfield, BX). Insert one bushing at each end of conduit. UL Approved. No. 75400 - Fits cable range: 14/2, 14/3, 12/2 No. 75401 - Fits cable range: 14/4, 12/3, 6/1, 4/1. No. Safe, non-conductive. Schedule 40 non-metallic socket type coupling for joining Schedule 40 non-metallic conduit. Will not rust or corrode. RoHS Compliance, UL Listed.
Carlon UA7AFB-CTN Standard Radius Conduit Elbow Halex 27511 Hit Lock Cable Connectors 1/2IN EMT COMPRS CONNECTOR
For use with nonmetallic solvent weld fittings. Nonconductive, impact, corrosion and sunlight resistant. UL Listed E35297. Fits NM Cable: #14/2, #14/3, #12/2, #10/2, #10/3. Snap-In, no screws or locknuts required. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. Design allows for two-step installation. Push into box and insert cable. UL Approved, CSA certified. Zinc die cast. Use to connect EMT conduit to steel outlet box, load center or other metal enclosure. UL Approved.
Halex 96152 1-Hole Snap-On Conduit Strap Halex 26155 1-Hole Snap-On Conduit Strap 1/2IN FLEX SET SCREW CONNECTOR
Indoor or outdoor applications. To support EMT conduit. Indoor or outdoor applications. To support EMT conduit. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure. UL Approved.
3/8IN FLX-BX SQUEEZE CONNECTOR STRAP CBL 1HOLE SRVC ENT      1 NM/SE CLAMP CONNECTOR
STRAP CBL 1HOLE SRVC ENT
Our Price : $1.69
1 NM/SE CLAMP CONNECTOR
Our Price : $1.79
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. UL Approved. Indoors or outdoors. Steel, use to secure service entrance cable (SEU, SER) to wood, masonry or similar surface. Fits non metallic cable number 14/2 to number 6/3 AWG or number 3/10/3 AWG or flex cord .450 to .730 inches diameter. With a 1/2" knockout. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Lis
Gardner Bender PPC-1525 1-Hole Cable Clamp Gardner Bender PPC-1538 1-Hole Cable Clamp Gardner Bender PPC-1550 1-Hole Cable Clamp
Flexible shape conforms to wires and cables. Holds harnesses, cables and tubing for construction, maintenance and assembly-line operations. Tough, durable, yet extremely lightweight with clean, smooth edges for easy handling. Working temperature range of -66 to 340 degrees F. Flexible shape conforms to wires and cables. Holds harnesses, cables and tubing for construction, maintenance and assembly-line operations. Tough, durable, yet extremely lightweight with clean, smooth edges for easy handling. Working temperature range of -66 to 340 degrees F. Flexible shape conforms to wires and cables. Holds harnesses, cables and tubing for construction, maintenance and assembly-line operations. Tough, durable, yet extremely lightweight with clean, smooth edges for easy handling. Working temperature range of -66 to 340 degrees F.
Gardner Bender PPC-1575 1-Hole Cable Clamp 2IN PLAST INSULATING BUSHING Gardner Bender PPC-1600 1-Hole Cable Clamp
Flexible shape conforms to wires and cables. Holds harnesses, cables and tubing for construction, maintenance and assembly-line operations. Tough, durable, yet extremely lightweight with clean, smooth edges for easy handling. Working temperature range of -66 to 340 degrees F. High impact thermoplastic. Flame retardant to 105 degrees C. Use with locknut to terminate threaded Rigid or IMC conduit to an outlet box. The rounded surface of the bushing prevents damage to wire insulation. Required by the NEC. UL Listed, CSA Approved. Flexible shape conforms to wires and cables. Holds harnesses, cables and tubing for construction, maintenance and assembly-line operations. Tough, durable, yet extremely lightweight with clean, smooth edges for easy handling. Working temperature range of -66 to 340 degrees F.
Carlon UA9AGR-CTN Standard Radius Conduit Elbow Carlon UA7AGR-CAR Standard Radius Conduit Elbow 1/2-1/2IN EMT-FLEX COUPLING
For use with nonmetallic solvent weld fittings. Nonconductive, impact, corrosion and sunlight resistant. For use with nonmetallic solvent weld fittings. Nonconductive, impact, corrosion and sunlight resistant. UL Listed E35297. Zinc die cast. Use to join EMT conduit to flexible metal conduit. Indoor use only. With UPC. UL Approved.
1/2IN EMT OFFSET CONNECTOR 1/2IN FLX-BX SQUEEZE CONNECTOR Halex 26211 1-Hole Conduit Strap
Zinc die cast. Use to connect EMT conduit to a metal outlet box or enclosure where an offset is desired. UL Approved. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. UL Approved. Steel, use to secure BX cable to wood, masonry or similar surface.
Halex 26210 1-Hole Service Entrance Strap 1-1/4 NM/SE CLAMP CONNECTOR Halex 61225 2-Hole Conduit Strap
Indoors or outdoors. Steel, use to secure service entrance cable (SEU, SER) to wood, masonry or similar surface. Fits non metallic cable number 6/3 to number 2/3 AWG flex cord .800 to 1.350 inches diameter or SE cable 3 conductor or 3 number 1/0 minimum; 3 conductor or 3 number 2/0 maximum. With 1/2" knockout. In a dry location, use to connect nonmetallic sheathed c To support EMT conduit where greater load bearing is required. Indoor or outdoor applications.
Halex 16010B Ground Clamp Thomas & Betts E994ER-CTN Conduit Offset Halex 26165 2-Hole Snap-On Conduit Strap
Indoor or outdoor applications. Use to secure the grounding wire to a 1/2" through 1" pipe. UL Listed. Wire size fits #10 - #2 AWG. Non-conductive. Will not rust or corrode. To support EMT conduit where greater load bearing is required. Indoor or outdoor applications.
Carlon E943K-CTN Terminal Adapter 1/2IN EMT COMPRS COUPLING Halex 26153 1-Hole Snap-On Conduit Strap
1/2IN EMT COMPRS COUPLING
Our Price : $1.99
Safe, non-conductive. For adapting schedule 40 non-metallic conduit to boxes, threaded fittings, metallic systems. Male threads on one end, socket end on the other. Will not rust or corrode. UL Listed, RoHS Compliance. Use to join two lengths of EMT conduit together. UL Approved. Indoor or outdoor applications. To support EMT conduit.
1/2IN FLEX-BX 90DEG CONNECTOR 3/4IN FLX-BX SQUEEZE CONNECTOR 3/4 RIGID CONDUIT CHASE NIPPLE
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure. 3/8" size fits 1/2" knock outs. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. UL Approved. Zinc die cast. Indoor or outdoor applications. Use to terminate threaded conduit to a knockout box or enclosure, where space within the box is limited. Used with a locknut to provide a short raceway between boxes or enclosures. UL and CSA approved.
CONNECTOR EMT 90DEG ZINC 1/IN CONNECTOR DPLX FLX N-MTL 3/8IN 3/4IN BOX SPACER
3/4IN BOX SPACER
Our Price : $2.19
Squeeze connectors 90 degree die cast zinc. Trade size: 1/2". For use in dry locations to bond flexible metal conduit or armored cable to a box or enclosure. Metallic construction insures mechanical protection for the raceway. UL Listed, CSA. In a dry location, use to connect two pieces of flexible armored cable (Greenfield or BX) to a steel outlet box or other metal enclosure, when using only one knock-out opening. UL Approved. Zinc die cast. Use as a raceway between two steel outlet boxes or other metal enclosures. UL Listed. Bulk packed.
3/4IN EMT COMPRS CONNECTOR Thomas & Betts E950FE-CTN Reducing Bushing Carlon UA7AGB-CAR Standard Radius Conduit Elbow
Zinc die cast. Use to connect EMT conduit to steel outlet box, load center or other metal enclosure. UL Approved. For connecting different sizes of conduit. Socket both ends, for reducing male Schedule 40/80 conduit runs or fittings to female. Non-conductive. Will not rust or corrode. For use with nonmetallic solvent weld fittings. Nonconductive, impact, corrosion and sunlight resistant. UL Listed E35297.
   
 
1 2 3 4