Home > CONSTRUCTION HARDWARE > JOIST HANGERS & CONNECTORS
Sort By:
1 2
USP Lumber JL26IF-TZ Standard Invert Flange Joist Hanger USP Lumber JL210IF-TZ Standard Invert Flange Joist Hanger USP Lumber PC12-BMC Plywood Clip
Speed prongs designed to temporarily position hangers on headers for more convenient nail fastening. G-185 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Speed prongs designed to temporarily position hangers on headers for more convenient nail fastening. G-185 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Features embossed dimples to provide 1/8" gap. G90 galvanizing; 20 gauge.
USP Lumber JL28IF-TZ Standard Invert Flange Joist Hanger USP Lumber RT16ATZ Double Plate Hurricane/Seismic Anchor USP Lumber JUS210-2TZ Double Shear Slant Joint Hanger
Speed prongs designed to temporarily position hangers on headers for more convenient nail fastening. G-185 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Anchor tie trusses and rafters to top plates and may be used to tie wood framing members to resist uplift and lateral forces. Typical Truss/rafter to double plate installation. Requires Meet ICC-ES ESR-1465 and FL817 codes. Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade county, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber B Reinforcement Corner Brace RH Tamlyn PCS716 Plywood Clip RH Tamlyn PCS12 Plywood Clip
These multi-purpose braces are designed to provide reinforcement for 90 degree wood-to-wood connections. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners; please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Replace wood blocking on roof sheathing. Tight fit for positive installation. Embossed dimples provide 1/8" gap needed to prevent panels from popping up as sheathing expands. G60 galvanizing finish. 20 Gauge - Boxed. Replace wood blocking on roof sheathing. Tight fit for positive installation. Embossed dimples provide 1/8" gap needed to prevent panels from popping up as sheathing expands. G60 galvanizing finish. 20 Gauge - Boxed.
RH Tamlyn PCS1532 Plywood Clip RH Tamlyn PC1532 Plywood Clip USP Lumber SKH28R-TZ Skewed Left Joist Hanger
Replace wood blocking on roof sheathing. Tight fit for positive installation. Embossed dimples provide 1/8" gap needed to prevent panels from popping up as sheathing expands. G60 galvanizing finish. 20 Gauge - Boxed. With built-in spacer for use when support spacing exceeds the maximum length of an unsupported edge. Boxed. Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICC-ES ESR-1781, FL13285, L.A. City RR25843 and Dade County, FL 11-0510.01 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments.
USP Lumber SKH28L-TZ Skewed Left Joist Hanger Squeek No More 1011345 Screw Set RH Tamlyn PCS58 Plywood Clip
Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICC-ES ESR-1781, FL13285, L.A. City RR25843 and Dade County, FL 11-0510.01 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments. Specially scored waxed screws. Scored head breaks off at the same place every time. Carded. Replace wood blocking on roof sheathing. Tight fit for positive installation. Embossed dimples provide 1/8" gap needed to prevent panels from popping up as sheathing expands. G60 galvanizing finish. 20 Gauge - Boxed.
Acorn IHW16100 Insulation Support Wire 16 in L USP Lumber NA11-5MC Joist Hanger Nail USP Lumber NA9-5MC Joist Hanger Nail
Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. 13 Gauge. Structurally rated. For use with MiTek/USP Lumber Connectors' products. For additional information including withdrawal load and allowable shear per nail, please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Structurally rated. For use with MiTek/USP Lumber Connectors' products. For additional information including withdrawal load and allowable shear per nail, please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
Squeek No More 1010543 Floor Squeak Repair Kit Acorn IHW24100 Insulation Support Wire 24 in L Deckmate 90166 Deck Bench Bracket with Bench Bracket
Eliminate squeaks quickly and permanently. Can be applied to 2nd floors, hardwood floors, carpet, and stairs. Each kit contains: 1 - alignment and depth control fixture, 50 - specially scored waxed screws, 1 - special driver bit, 1 - complete instruction kit. Carded. Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. 13 Gauge. You determine the size. Connect with railing brackets with 2x4 and 2x6 lumber to easily add a bench to any size or shape deck. Gain increased seating area while using only 7" of deck space. Assembled unit stands 36"H for deck railing, seat is 17"H. Quick and easy to assemble using basic tools. Includes bench bracket, hardware and instructions. LUMBER NOT INCLUDED.
USP Lumber RS20-R Coiled Strap ANGLE 2X4IN TRIPLE ZINC 12GA  Acorn IHW16500 Insulation Support Wire 16 in L
Enables cut-to-length convenience for job site needs. G90 galvanizing finish. 1-1/2" nail spacing. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Provides a 90? connection for medium/heavy duty applications; stronger than angled nailing or screw fastening; help ensure joints are consistently straight and strong. Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. 13 Gauge.
RH Tamlyn BT 22SP Corrugated Straight Brick Wall Tie RH Tamlyn BT22ZZSP Corrugated Scalloped Zig Zag Brick Wall Tie Hopkins 90128 Shelf Link 4 ft L x 2 ft W
Masonry accessory used to tie a brick veneer to the exterior of the house. 2 holes provide for nailing on one end; other end is bent to lie between the mortar joints. Follow local codes for spacing. 6-3/8" x 7/8". Boxed. Masonry accessory used to tie a brick veneer to the exterior of the house. 2 holes provide for nailing on one end; other end is bent to lie between the mortar joints. Follow local codes for spacing. 6-3/8" x 7/8". You can determine the size and configuration, just add 2x4's to the ShelfLinks to make functional and custom shelving in any length, height and configuration. Made of structural resin. Can support spans up to 8'. Includes ShelfLinks, hardware and instructions. LUMBER NOT INCLUDED.
RH Tamlyn BT28ZZ5SP Corrugated Scalloped Zig Zag Brick Wall Tie RH Tamlyn BT28500SP Corrugated Straight Brick Wall Tie ANGLE 2X6IN TRIPLE ZINC 12GA
Masonry accessory used to tie a brick veneer to the exterior of the house. 2 holes provide for nailing on one end; other end is bent to lie between the mortar joints. Follow local codes for spacing. 6-3/8" x 7/8". Masonry accessory used to tie a brick veneer to the exterior of the house. 2 holes provide for nailing on one end; other end is bent to lie between the mortar joints. Follow local codes for spacing. 6-3/8" x 7/8". Boxed. Provides a 90? connection for medium/heavy duty applications; stronger than angled nailing or screw fastening; help ensure joints are consistently straight and strong.
USP Lumber JL24 Standard Joist Hanger USP Lumber MP34 Framing Angle Deckmaster DMP125-10 Hidden Deck Bracket Kit
G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Use for joist/header installations. Does not have tabs. G90 galvanizing finish. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505; ICBO 5736; DSA PA-076; Dade County, FL 01-0417.11; and  L.A. City RR25303 codes. 18 Gauge. System eliminates the damage to deck boards by hiding all fasteners beneath deckboards. Holds boards tight to eliminate any surface penetration. No moisture can enter deckboards or joists and cause nail penetration. No moisture can enter deckboards or joists and cause nail or screw pop-ups or deck rot. No stains or splinters form around fastener holes. Corrosion resistance. Powder coating's natural wood color blends with the understructure of balconies. For: 3/4" thick boards, composites less than 1-1/8", and any hollowcore composites. Consumer pack includes: 10 brackets, (120) 10 x 1" deck board screws, (110) 8 x 1" joist screws, and a pro bit tip.
Deckmaster DMP175-10 Hidden Deck Bracket Kit Deckmaster DMP100-10 Hidden Deck Bracket Kit USP Lumber RT7A Double Plate Hurricane/Seismic Anchor
System eliminates the damage to deck boards by hiding all fasteners beneath deckboards. Holds boards tight to eliminate any surface penetration. No moisture can enter deckboards or joists and cause nail penetration. No moisture can enter deckboards or joists and cause nail or screw pop-ups or deck rot. No stains or splinters form around fastener holes. Corrosion resistance. Powder coating's natural wood color blends with the understructure of balconies. For: 3/4" thick boards, composites less than 1-1/8", and any hollowcore composites. Consumer pack includes: 10 brackets, (120) 10 x 1" deck board screws, (110) 8 x 1" joist screws, and a pro bit tip. System eliminates the damage to deck boards by hiding all fasteners beneath deckboards. Holds boards tight to eliminate any surface penetration. No moisture can enter deckboards or joists and cause nail penetration. No moisture can enter deckboards or joists and cause nail or screw pop-ups or deck rot. No stains or splinters form around fastener holes. Corrosion resistance. Powder coating's natural wood color blends with the understructure of balconies. For: 3/4" thick boards, composites less than 1-1/8", and any hollowcore composites. Consumer pack includes: 10 brackets, (120) 10 x 1" deck board screws, (110) 8 x 1" joist screws, and a pro bit tip. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
Simpson Strong-Tie LSTA Light Duty Strap Tie USP Lumber JL26 Standard Joist Hanger Acorn IHW24500 Insulation Support Wire 24 in L
Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. 13 Gauge.
USP Lumber LSTA12 Light Capacity Strap Tie USP Lumber RT3A Double Plate Hurricane/Seismic Anchor USP Lumber JUS28 Double Shear Slant Joist Hanger
Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Ties trusses and rafters to top plates either left or right handed. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. G90 galvanizing finish. Requires 8d nails for installation in plate and rafter/truss. Meets ICC-ES ESR-1465 and FL817 codes. 18 Gauge. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
Hopkins 90110 Comfortable Flip Top Bench Table USP Lumber PCP Post Cap USP Lumber RT Hurricane/Seismic Anchor
Make a comfortable, sturdy bench and a table up to 8' long. Just add 2x4 lumber pieces. Flips and locks from a bench to a table in seconds without using tools. Slide lock safely secures and locks in position. Made of maintenance free structural resin. Use only one or slide two Bench Tables together for a full size picnic table. Good for small porches and decks. Assembled unit stands 34"H in the bench position, 31"H in the table position and both with 17.5"H seat. Includes Bench Table legs, hardware and instructions. LUMBER NOT INCLUDED. Seamless, keeps water off post tops to protect wood from moisture damage. Corrosion-proof and paintable. Requires one 8d HDG or 10d HDG nail for installation. 3-5/8"W - For 4 x 4 Post/Column. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
Hopkins 90158 Workbench Kit USP Lumber KHL33 Heavy Joist Angle USP Lumber ST1-TZ Mud Sill Anchor
Create a workbench, worktable or power tool stand. Add 2x4's plywood or particleboard to make a workbench, worktable or power tool stand in any length or width up to 8'L x 4'W. Simple assembly in less than an hour with only powered screwdriver and a saw. Only straight, 90-degree cuts required, no miter or angles. Made of structural resin.  Kit includes: 4 legs, hardware and instructions. LUMBER AND SHELF LINKS NOT INCLUDED. Designed for heavy-duty reinforcement of 90 degree framing intersections. USP primer finish. Requires (2) 5/8" bolts for installation. Meets ICBO 2725, L.A. City RR 25104. 7 Gauge. For securing mudsills and framing into concrete slabs or poured stemwalls. Not for block installation or securing concrete sections together between cold joints. Features prebent base flange for proper anchoring into concrete. Use a minimum of 2 anchors per mudsill within 12" of the end of each section. Meets  NER 530 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber JA1 Joist Angle USP Lumber JL28 Standard Joist Hanger USP Lumber JA1-TZ Framing Angle
Used to strengthen framing in various applications or to support joists where stirrup style hangers cannot be installed. Requires 10d x 1-1/2 nails for installation. Meets ICBO, SBCCI, BOCA - NER 505; L.A. City RR25303, DSA PA-076; and Dade County, FL 98-0421.06 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 16 Gauge. G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Used to strengthen framing in various applications or to support joists where stirrup style hangers cannot be installed. Requires 10d x 1-1/2 nails for installation. Meets ICBO, SBCCI, BOCA - NER 505; L.A. City RR25303, DSA PA-076; and Dade County, FL 98-0421.06 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 16 Gauge.
U-CLIP 2X-2X TRIPLE ZINC      USP Lumber PL4 Protection Plate USP Lumber JUS28-TZ Double Shear Slant Joint Hanger
A clip connects a 2x wood member to the face of another wood member; 20 gauge; G-185 galvanizing finish; requires (6) USP LumberLok LL915 (#9 x 1-3/8" long) wood screws not included. Easy-to-install for protecting plumbing and power or communication wiring from screw or nail penetration. Conforms to National Electric Code. 16 Gauge - 1/16" Thickness. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber BL Corner Brace USP Lumber JUS210 Double Shear Slant Joist Hanger USP Lumber LSTA18 Light Capacity Strap Tie
Reinforces 90 degree wood-to-wood connections. G90 galvanizing finish. Requires 16d nails for installation. 12 Gauge. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
STRAP TIE 3-1/4X16IN TRI-ZINC USP Lumber JL210 Standard Joist Hanger USP Lumber SMP Fence Post Connector
Wide strapping; requires (16) WS15-HDG nails for installation. Meets 110 codes. G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Reinforcement brackets used to repair rotted or damaged fence posts. Step-by-step instructions labeled onto each. Green corrosion resistant paint finish. 13 Gauge - For 4 x 4 Posts.
HANGER RIDGE RAFTER 18 GAUGE  STRAP TIE 3 X 7IN TRIPLE ZINC USP Lumber RS150 Coiled Strap
Supports rafter pitches up to 7:12 (30?). Nesting top flange for installation on 2x support beams. Use all specified fasteners. The rafter end at the ridge must be plumb cut to achieve published loads. Optional diamond nail holes can be used to faster RR to end of rafter before settling rafter into place. Medium capacity; requires (20) 10d x 1-1/2" HDG nails for installation. Meets 130 codes. Enables cut-to-length convenience for job site needs. G90 galvanizing finish. 1-1/2" nail spacing. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber JUS24 Double Shear Slant Joist Hanger USP Lumber KNS1 Protection Plate USP Lumber T6 T-Post Strap
Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Easy to install for protecting plumbing and power or communication wiring from screw or nail penetration. 16 gauge, 1/16" thick. Conforms to National Electric Code. Medium-duty straps connect beams to posts. Requires either (3) 1/2" bolts or (12) 16d nails for installation. Triple Zinc straps require HDG bolts or 16d HDG nails for installation.
USP Lumber JUS26 Double Shear Slant Joist Hanger USP Lumber PB 2-Piece Split Post Cap USP Lumber PB66-6TZ 1-Piece Post Cap 18 ga T
Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For light-duty post-to-beam connections. Quick and easy installation on decks, carports and other projects. Use two caps for each installation project to act as a unit. Designed to work with single, solid sawn beams, but can be used with build-up beams made of 2x lumber and shims fastened. "-TZ" following item number indicates Triple Zinc finish. "-GC" following item number indicates Gold Coat finish. Meets ICC-ES ESR-1781, FL18285 and L.A. City RR25843 codes. For additional information including allowable loads loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For light-duty post-to-beam connections. Quick and easy installation on decks, carports and other projects. Use two caps for each installation project to act as a unit. Designed to work with single, solid sawn beams, but can be used with build-up beams made of 2x lumber and shims fastened. "-TZ" following item number indicates Triple Zinc finish. "-GC" following item number indicates Gold Coat finish. Meets ICC-ES ESR-1781, FL18285 and L.A. City RR25843 codes. For additional information including allowable loads loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber JUS26-TZ Double Shear Slant Joint Hanger USP Lumber THF23925 Joist Hanger USP Lumber EBG Elevated Post Base
Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Designed to provide lateral support for the top chords of I-Joists in depths up to 16". G90 galvanizing finish. Meets ICC-ES ESR-1781, FL13285 and L.A. City RR25843 codes. Install 10d x 1-1/2" nails into joist through raised dimple at 45 degree angle. For THF Min, fill all round nail holes. For THF Max, fill all round and diamond holes. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Allows installer to pre-align posts and to preset post height above concrete floors or footings. Eliminates post-to-concrete contact for reduced moisture damage. Nails fasten to posts for carports, decks or porches. EPB is welded and primed. EBG is galvanized for added corrosion resistance. Not recommended for fence posts or unrestrained (not fixed or fastened at top) applications.. Requires (8) 16d nails for EPB4408, (12) 16d nails for EPB6608, (8) 16d HDG nails for EBG44-TZ . Meets SBCCI, BOCA - NER 505, ICBO 5736, L.A. City RR 25303 and DSA PA-076 codes. For additional information including allowable loads, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber ST12 Strap Tie USP Lumber MPA1 Framing Angle USP Lumber EPB Elevated Post Base
Connects wood framing to resist tension forces. G90 galvanizing finish. ST Medium-duty series require 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. 16 Gauge. Use for joist to header, rafter to plate, stud to plate or 1" foamboard installations. Achieves continuous load path in high wind and seismic resistant construction. Enables quick field adjustments for 2 and 3-way connections. Tabs enable two and three-way connections. Bend tabs only once. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505, ICBO 5736, DSA PA-076, Dade County, FL 01-417.11 and  L.A. City RR25303 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Allows installer to pre-align posts and to preset post height above concrete floors or footings. Eliminates post-to-concrete contact for reduced moisture damage. Nails fasten to posts for carports, decks or porches. EPB is welded and primed. EBG is galvanized for added corrosion resistance. Not recommended for fence posts or unrestrained (not fixed or fastened at top) applications.. Requires (8) 16d nails for EPB4408, (12) 16d nails for EPB6608, (8) 16d HDG nails for EBG44-TZ . Meets SBCCI, BOCA - NER 505, ICBO 5736, L.A. City RR 25303 and DSA PA-076 codes. For additional information including allowable loads, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber N16 Joist Bridging USP Lumber JUS24-TZ Double Shear Slant Joint Hanger USP Lumber FB24-TZ Fence Bracket
Spans 2 joists per unit, typically used for bridging or bracing I-joists. Must be installed before subfloor sheathing to reduce joist movement and subsequent floor noise. G90 galvanizing finish. Requires 8d x 1-1/2 nails. Meets ICC-ES ESR-1781, FL13285 and L.A. City RR25843 codes. For additional information including I-joist installation, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 22 Gauge. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Provides stronger fence connections and simplifies fence assembly. Can be installed before posts are set to help ensure uniform spacing and alignment. Requires five 6d HDG fasteners for rails and three 8d HDG fasteners for posts.
USP Lumber RT Hurricane/Seismic Anchor ANGLE 2X-2X TRIPLE ZINC 16GA  USP Lumber MPA1 Framing Angle
Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc finish requires 8d HDGnails for installation in plate and rafter/truss and Gold Coat anchor requires N8-GC nails. 1-9/16"W x 2-5/8"H opening. Meets ICC-ES ESR-1465, FL817 and Dade County, FL 07-0306.10 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Contractors charts in the Orgill paper catalog R7 for reference pages. 18 GAUGE - 5-1/4"H. An angle connects two 2x wood members at 90? angles; G185 galvanizing finish; requires (8) USP LumberLok LL915 (#9 x 1-3/8" long) wood screws not included. Use for joist to header, rafter to plate, stud to plate or 1" foamboard installations. Achieves continuous load path in high wind and seismic resistant construction. Enables quick field adjustments for 2 and 3-way connections. Tabs enable two and three-way connections. Bend tabs only once. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505, ICBO 5736, DSA PA-076, Dade County, FL 01-417.11 and  L.A. City RR25303 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber JUS26-2 Double Shear Slant Support Joist Hanger USP Lumber SFP30 Fence Post Connector USP Lumber JUS210-TZ Double Shear Slant Joint Hanger
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade county, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Install wooden posts permanently or temporarily without digging.  For heavy-duty applications such as long runs of fencing, corner and gate posts, larger wooden gym sets, detached patio decking, wooden sidewalks, seasonal docks, and more. Removable Forcefit clamps and 2-piece construction, increases unit strength and eliminates welds which are potential weak spots. Reverse spike blades offer lateral soil resistance, increased stability, and allows driving without rotating for easy post alignment. Welded steel construction with high tech baked-on finish, rust resistant and 100% environmentally safe. Application information and installation instructions labeled on each. Green Commission finish. 13 Gauge - For 4 x 4 Posts. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber THF23118 Joist Hanger USP Lumber T6-TZ T-Post Strap USP Lumber WBT Flat Wall Brace
Designed to provide lateral support for the top chords of I-Joists in depths up to 16". G90 galvanizing finish. Meets ICC-ES ESR-1781, FL13285 and L.A. City RR25843 codes. Install 10d x 1-1/2" nails into joist through raised dimple at 45 degree angle. For THF Min, fill all round nail holes. For THF Max, fill all round and diamond holes. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Medium-duty straps connect beams to posts. Requires either (3) 1/2" bolts or (12) 16d nails for installation. Triple Zinc straps require HDG bolts or 16d HDG nails for installation. For use on stud walls to resist racking during framing. Can be used to replace code prescribed 1 x 4 wood let-in bracing as a framing aid. Rolled edges and t-style design give strength, rigidity, and eliminate sharp, sheared edges. Framing aid only; Not a substitute for structural shearwall components. G90 galvanizing finish. Requires two 8d nails for each plate, one 8d nail for each stud. 511-pound max for No.WBT12. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. Max load is the max load vector applied at top of stud wall section, not to exceed 25'L, resisted by the combination of wall brace straps installed. Load based on lumber with a 0.50 specific gravity and 19% or less moisture content. 22 Gauge.
USP Lumber CPB Composite Post Base USP Lumber LSTA24 Light Capacity Strap Tie USP Lumber TFL2595 Joist Hanger
Provides a raised base that elevates wood posts above concrete surfaces to avoid moisture from ground contact. Single-piece design made from composite material; will not corrode. Open center enables installation of metal rod from concrete into post. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning moment loads. Requires (4) 10d HDG nails. ACQ approved. Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Features 1-1/2" top flange depth that accommodates all header types as well as back-to-back installations. Features "Seat Cleat" for quick, positive seating. G90 galvanizing finish. Meets ICC-ES ESR-1831 codes. Header requires (6) 10d nails and joist requires (2) 10d x 1-1/2 nails for installation. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. 18 Gauge.
USP Lumber BL Reinforcement Corner Brace USP Lumber L6TZ L-Post Strap USP Lumber JUS210-2 Double Shear Slant Support Joist Hanger
Reinforces 90 degree wood-to-wood connections. G90 galvanizing finish. Requires 16d nails for installation. 12 Gauge. Medium-duty straps connect beams to posts. Requires either 1/2" bolts or 16d nails for installation. Triple Zinc straps require HDG bolts or 16d HDG nails for installation. Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade county, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber ST2-TZ Mud Sill Anchor USP Lumber JUS26-2TZ Double Shear Slant Joint Hanger USP Lumber MSTA18-TZ Medium Capacity Strap Tie
For securing mudsills and framing into concrete slabs, poured stemwalls, or concrete block. Not for securing concrete sections together between cold joints. Features prebent base flange for proper anchoring into concrete. Use a minimum of 2 anchors per mudsill within 12" of the end of each section. Meets NER 530 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade county, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Requires 10d nails for installation. Meets ICC-ES ESR-1781, FL13285 and L.A. City RR25843 codes.
USP Lumber PA(E) 2-Sided Post Anchor USP Lumber PA44-TZDP Post Anchor USP Lumber JUS28-2 Double Shear Slant Joist Hanger
Used to secure wood posts to concrete footings and to provide moisture damage protection. 2-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR 25836 codes. Used to secure wood posts to concrete footings and to provide moisture damage protection. 4-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Drain slots allow the anchors to shed water. Triple zinc finish for ACQ pressure treated lumber. Not for fence posts or unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade county, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber SCA Stair Angle USP Lumber THF25140 Joist Hanger USP Lumber BL Corner Brace
Simplifies stair construction and eliminate the need to calculate and notch stair stringers. Stronger and safer than wood blocking, and the angle and fasteners are hidden from view. Use the SCA9 for single 2x10 stair treads and SCA10 for double 2 x 6 stair treads. Requires 1/4" x 1-1/2" lag bolts. Meets ICC-ES ESR-1280, FL11664 and L.A. City RR25749 codes. For additional information on installation, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Designed to provide lateral support for the top chords of I-Joists in depths up to 16". G90 galvanizing finish. Meets ICC-ES ESR-1781, FL13285 and L.A. City RR25843 codes. Install 10d x 1-1/2" nails into joist through raised dimple at 45 degree angle. For THF Min, fill all round nail holes. For THF Max, fill all round and diamond holes. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Reinforces 90 degree wood-to-wood connections. G90 galvanizing finish. Requires 16d nails for installation. 12 Gauge.
USP Lumber PA(E) 2-Sided Post Anchor USP Lumber WE44-TZ Wet Post Anchor USP Lumber TFL25118 Joist Hanger
Used to secure wood posts to concrete footings and to provide moisture damage protection. 2-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR 25836 codes. Secures posts to concrete in light-duty and medium-duty applications such as patio covers, carports or decks. Formed, one-piece design includes embossing for additional lateral strength. Not  for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires (2) 1/2" HDG bolts or (12) HDG nails for fastening to post. Meets SBCCI, BOCA - NER 530 & NER 608, ICBO 5700, ICBO 2039, ICBO 5531, FL821, FL822, L.A. City RR 25337, and DSA PA-076 codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Features 1-1/2" top flange depth that accommodates all header types as well as back-to-back installations. Features "Seat Cleat" for quick, positive seating. G90 galvanizing finish. Meets ICC-ES ESR-1831 codes. Header requires (6) 10d nails and joist requires (2) 10d x 1-1/2 nails for installation. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. 18 Gauge.
USP Lumber FA3-TZ Foundation Anchor USP Lumber MBG1016 Grip Tooth Joist Bridging USP Lumber PA46E-TZ Post Anchor
For securing mudsills and framing into concrete slabs. Do not rely-on for securing concrete sections together between cold joints. Features split flange for nailing to both mudsill and stud for greater framing versatility. Use a minimum of 2 anchors per mudsill within 12" of the end of each section. Meets ICC-ES ESR-2787 codes For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Special teeth grip joists for easy single-nail installation. Can be installed before or after subfloor is in place (sheathing) to reduce joist movement and subsequent floor noise. G90 galvanizing finish. Requires one 8d x 1-1/2 nail. Meets ICC-ES ESR-1781, FL13285 and L.A. City RR25843 codes. For additional information on standard lumber installation, Please See USP Lumber Connectors charts in the Orgill paper catalog D10 Reference Pages. 22 Gauge - 2 x 10 Joist Size. Used to secure wood posts to concrete footings and to provide moisture damage protection. 2-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR 25836 codes.
USP Lumber RT16A Double Plate Hurricane/Seismic Anchor USP Lumber MSTA24-TZ Medium Capacity Strap Tie USP Lumber A3 Framing Angle
Anchor tie trusses and rafters to top plates and may be used to tie wood framing members to resist uplift and lateral forces. Typical Truss/rafter to double plate installation. Requires Meet ICC-ES ESR-1465 and FL817 codes. Requires 10d nails for installation. Meets ICC-ES ESR-1781, FL13285 and L.A. City RR25843 codes. Eliminates toenailing and increases strength. Requires 10d x 1-1/2" nails for installation. 1-7/16"W1 X 1-7/16"W2 X 2-3/4"L - 18 GAUGE. Meets ICC-ES ESR-2104, FL820 and L.A. City RR25745 codes.
USP Lumber D Post Anchor USP Lumber LSTA30 Light Capacity Strap Tie USP Lumber SCA Stair Angle
Secures nominal sized post to wood surfaces offering some lateral and uplift resistance. May be used only for intermediate posts between fully anchored corner/end posts in rail system. Not Recommended for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d HDG fasteners for post and 16d HDG fasteners for base. Meets ICBO 2039 and L.A. City RR23888 codes. For additional information including allowable loads, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Simplifies stair construction and eliminate the need to calculate and notch stair stringers. Stronger and safer than wood blocking, and the angle and fasteners are hidden from view. Use the SCA9 for single 2x10 stair treads and SCA10 for double 2 x 6 stair treads. Requires 1/4" x 1-1/2" lag bolts. Meets ICC-ES ESR-1280, FL11664 and L.A. City RR25749 codes. For additional information on installation, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber CSH-TZ Concealed Stringer Hanger USP Lumber BP583 Standard Bearing Plate USP Lumber SDJT14-TZ Deck Post Tie
Concealed stair stringer hanger provides a method of connecting a stringer with a hidden hanger. The seat of the hanger is adjustable to match the slope of the stair stringer. Triple Zinc finish. Requires (8) 10d x 1-1/2 HDG nails for header and (5) 10d x 1-1/2 HDG nails for joist. 18 Gauge. Pending IAPMO-ES evaluation. Designed to meet code requirements for mudsill-to-foundation and stud-to-foundation connections. Secures 2x joist to posts. Requires 16d HDG nails or 5/8" HDG bolts for installation. 14 Gauge.
USP Lumber TSX24 Truss Spacer USP Lumber JUS28-3TZ Double Shear Slant Joist Hanger USP Lumber LSTA36 Light Capacity Strap Tie
Fast and accurate spacing guides for trusses, rafters or floor joists. Lightweight and compact, eliminates need to mark layouts on bearing plates, improves installation speed and helps to eliminate spacing errors. Do not rely on TSX  for bracing. Requires one 8d nail per end. 10'L overall; 24" O.C. spacing. 22 Gauge - 5 Sections/Piece. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners; please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber JUS210-3TZ Double Shear Slant Joist Hanger USP Lumber C66-TZ 1-Piece Post Beam Cap USP Lumber MSTA36-TZ Medium Capacity Strap Tie
Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners; please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For light-duty post-to-beam connections. Quick and easy installation on decks, carports and other projects. One piece, designed to work with single, solid sawn beams, but can be used with build-up beams made of 2x lumber and shims fastened together to act as a unit. Requires 16d HDG nails for installation. Meets ICC-ES ESR-1280, FL11664, L.A. City RR25749 and Dade County, FL 07-0306.06 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 18 GAUGE. Requires 10d nails for installation. Meets ICC-ES ESR-1781, FL13285 and L.A. City RR25843 codes.
USP Lumber THF25925 Joist Hanger USP Lumber HCPRS Hurricane/Seismic Anchor USP Lumber PA66-TZDP Post Anchor
Designed to provide lateral support for the top chords of I-Joists in depths up to 16". G90 galvanizing finish. Meets ICC-ES ESR-1781, FL13285 and L.A. City RR25843 codes. Install 10d x 1-1/2" nails into joist through raised dimple at 45 degree angle. For THF Min, fill all round nail holes. For THF Max, fill all round and diamond holes. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Used to tie trusses and rafters to top plates, and may be used to tie wood framing members to resist uplift and lateral forces. G90 galvanizing finish. 1-9/16"W opening. Meets ICC-ES ESR-1881, FL821 and L.A. City RR25779 codes. 18 Gauge - 5-1/4"W. Used to secure wood posts to concrete footings and to provide moisture damage protection. 4-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Drain slots allow the anchors to shed water. Triple zinc finish for ACQ pressure treated lumber. Not for fence posts or unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes.
USP Lumber SKH28L Skewed Left Joist Hanger USP Lumber SKH28R Skewed Right Joist Hanger USP Lumber ICPL58-TZ Protection Plate
Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICC-ES ESR-1781, FL13285, L.A. City RR25843 and Dade County, FL 11-0510.01 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments. Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICC-ES ESR-1781, FL13285, L.A. City RR25843 and Dade County, FL 11-0510.01 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments. Easy-to-install plates protect plumbing and power/communication wiring from nail or screw penetration. 16 Gauge - 1/16" Thickness.
USP Lumber ICPL516-TZ Protection Plate USP Lumber MPA1-GC Framing Angle USP Lumber CPB Composite Post Base
Easy-to-install plates protect plumbing and power/communication wiring from nail or screw penetration. 16 Gauge - 1/16" Thickness. Use for joist to header, rafter to plate, stud to plate or 1" foamboard installations. Achieves continuous load path in high wind and seismic resistant construction. Enables quick field adjustments for 2 and 3-way connections. Tabs enable two and three-way connections. Bend tabs only once. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505, ICBO 5736, DSA PA-076, Dade County, FL 01-417.11 and  L.A. City RR25303 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Provides a raised base that elevates wood posts above concrete surfaces to avoid moisture from ground contact. Single-piece design made from composite material; will not corrode. Open center enables installation of metal rod from concrete into post. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning moment loads. Requires (4) 10d HDG nails. ACQ approved.
USP Lumber SUH44 Joist Hanger USP Lumber SKH26R-TZ Skewed Right Joist Hanger USP Lumber LSSH15-TZ Slope/Skew Joist Hanger
Framing connectors for floor systems, deck projects, other joist to header applications, and for light truss applications. Speed prongs designed to temporarily position hangers on headers for more convenient nail fastening. 16 gauge steel construction. G90 galvanizing finish. Meets ICC-ES ESR-1280, FL11664 and L.A. City RR25749 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICC-ES ESR-1781, FL13285, L.A. City RR25843 and Dade County, FL 11-0510.01 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments. Connects rafters to ridge beams in vaulted roof structures; field adjustable to meet a variety of skew and slope applications; slopes to any pitch to 45 degrees up or down and skews up to 45 degrees right or left.  For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. 18 Gauge.
USP Lumber MP9-TZ Framing Angle USP Lumber THF25112 Joist Hanger USP Lumber SKH26L-TZ Skewed Left Joist Hanger
May be field adjusted by hand from 0 to 135 degrees, giving framers and do-it-yourselfers flexibility in applications. Bend angle only once. G90 galvanized finish. 10d HDG nails required for installation. Meets SBCCI, BOCA - NER 530, ICBO 5700, FL822, L.A. City RR 25337, DSA PA-06 codes. Designed to provide lateral support for the top chords of I-Joists in depths up to 16". G90 galvanizing finish. Meets ICC-ES ESR-1781, FL13285 and L.A. City RR25843 codes. Install 10d x 1-1/2" nails into joist through raised dimple at 45 degree angle. For THF Min, fill all round nail holes. For THF Max, fill all round and diamond holes. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICC-ES ESR-1781, FL13285, L.A. City RR25843 and Dade County, FL 11-0510.01 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments.
USP Lumber DTB Deck Tie Bracket USP Lumber D66-TZ Post Anchor USP Lumber JUS28-2TZ Double Shear Slant Joist Hanger
Used to reinforce the connection of rail posts to a deck. Also provides lateral strength of deck-to-ledger attachment by securing deck to house framing. Installs with 1/2" anchor bolt (not included) and 8" WS15-GC Wood screws (included). G185 galvanizing finish. Pending IAPMO-ES ER-0200 and FL14500 codes. Secures nominal sized post to wood surfaces offering some lateral and uplift resistance. May be used only for intermediate posts between fully anchored corner/end posts in rail system. Not Recommended for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d HDG fasteners for post and 16d HDG fasteners for base. Meets ICBO 2039 and L.A. City RR23888 codes. For additional information including allowable loads, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade county, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber C 1-Piece Post Cap USP Lumber MB16 Snap-On Joist Bridging USP Lumber O16 Joist Bridging
For light-duty post-to-beam connections. Quick and easy installation on decks, carports and other projects. One piece, designed to work with single, solid sawn beams, but can be used with build-up beams made of 2x lumber and shims fastened together to act as a unit. Requires 16d HDG nails for installation. Meets ICC-ES ESR-1280, FL11664, L.A. City RR25749 and Dade County, FL 07-0306.06 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 18 GAUGE. No-nail bridging. Place in existing floor system where joist movement is suspected to reduce movement and subsequent floor noise. 2 piece construction creates a solid diagonal brace against joist movement. G90 galvanizing finish. Shipped as 1 piece that easily breaks into 2 pieces at center for proper installation. Meets ICC-ES ESR-1781, FL3285 and L.A. City RR25843 codes. For additional information on standard lumber installation, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 22 Gauge - 2 x 8-10-12 Joist Size. Spans three joists in under/over installation; prong teeth in the center helps reduce nailing. G90 galvanizing finish; bridging should be installed on floor joists with a nominal depth-to-thickness ratio of 5 to 6 or more (2055 National Design Specification for Wood Construction; Section 4.4.1). Install prior to subfloor sheathing; use (2) 8d x 1-1/2" nails at each end. Fully seat nails to avoid any movement against the bridging and subsequent floor noise. 18 Gauge.
USP Lumber AC5-TZ Framing Angle USP Lumber AC9-TZ Framing Angle USP Lumber JNP24 Joiner Nail Mending Plate
For general-purpose reinforcements of many framing connections. G185 galvanized finish. Can be used in both new construction and retrofit applications. Staggered nail patterns reduce wood splitting and allows installation on both sides of the supported member. Triple Zinc clips require 10d HDG or 16d HDG nails.  Meets ICC-ES ESR-2104, FL820 and L.A. City RR25745 codes. For additional information including allowable loads and number of fasteners, please see USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. For general-purpose reinforcements of many framing connections. G185 galvanized finish. Can be used in both new construction and retrofit applications. Staggered nail patterns reduce wood splitting and allows installation on both sides of the supported member. Triple Zinc clips require 10d HDG or 16d HDG nails.  Meets ICC-ES ESR-2104, FL820 and L.A. City RR25745 codes. For additional information including allowable loads and number of fasteners, please see USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Prong plates with angled, hammer-in prongs. Joins flat surfaces of 2 or more wood members. G90 galvanizing finish. Not intended for structural use OR in truss assembly. No load ratings assigned. 18 Gauge.
Deckmaster DMP100-100 Hidden Deck Bracket Kit Deckmaster DMP175-100 Hidden Deck Bracket Kit USP Lumber TDX2-TZ Holdown
System eliminates the damage to deck boards by hiding all fasteners beneath deckboards. Holds boards tight to eliminate any surface penetration. No moisture can enter deckboards or joists and cause nail penetration. No moisture can enter deckboards or joists and cause nail or screw pop-ups or deck rot. No stains or splinters form around fastener holes. Corrosion resistance. Powder coating's natural wood color blends with the understructure of balconies.  Contractor pack includes: 100 brackets, (1200) 10 x 1-1/4" deck board screws, (1100) 8 x 1" joist screws, and a pro bit tip. Use the Contractor pack for large decks. System eliminates the damage to deck boards by hiding all fasteners beneath deckboards. Holds boards tight to eliminate any surface penetration. No moisture can enter deckboards or joists and cause nail penetration. No moisture can enter deckboards or joists and cause nail or screw pop-ups or deck rot. No stains or splinters form around fastener holes. Corrosion resistance. Powder coating's natural wood color blends with the understructure of balconies.  Contractor pack includes: 100 brackets, (1200) 10 x 1-1/4" deck board screws, (1100) 8 x 1" joist screws, and a pro bit tip. Use the Contractor pack for large decks. Used to tie first and second story framing together, anchor studs to foundations or to tie purlins to masonry or concrete. Features self-jigging, formed design with code required distances built-in. Requires 7/8", 5/8, and 3/4" bolts for installation. Meets IAPMO-ES ER-0200 and FL14500 codes. For additional information including allowable loads and number of fastener, please see USP Lumbar Connectors charts in the Orgill paper catalog R7 Reference Pages.
   
 
1 2